Gas detected | Ozone |
Sensing element | Semiconductor ozone gas sensor |
Power Supply | 24VAC/VDC±10% |
Consumption | 2.2 W |
Temperature sensor | NTC |
Warm up time | 96 hours (first time)?? 1 hour(operation) |
Signal Update | 2s |
O3 Measuring Range | 10~500ppb |
O3 measuring precision | ±15ppb + 20% reading (15~35℃/30~60%RH) |
Six indicator lights | The first green indicator light:O3≤49ppb The first and the second green indicator lights:50ppb~99ppb The first yellow indicator light:100ppb~199ppb The first and the second yellow indicator lights:200ppb~299ppb The first red indicator light:300ppb~399ppb The first and the second indicator lights:O3 ≥400ppb |
Modbus interface | Modbus RS485 protocol with19200bps(default), 15KV antistatic protection, independent base address, 31 max network nodes |
Relay output(optional) | One dry contact output, rated switching current 2A(resistance load). Provide four ozone ranges to be selected to control the relay turn-on/turn-off ?(50ppb /100ppb-default / 200ppb/ 300ppb) |
Analog output(optional) | 1X0~10VDC or 4~20mA for ozone measurements |
Operation temperature | 5~50℃ (41~122℉) |
Operation humidity | 0~80%RH,non condensing |
Weight | 190g |
Dimensions | 100mm×80mm×28mm |
Installation standard | 65mm×65mm or 2”×4” wire box |
Housing/ IP rate | PC/ABS plastic fireproof material, IP30 |
Standard | CE-Approval EN60730-1:2000 +A1:2004 + A16:2007 + A2:2008 Directive: 2004/108/EC |
- - - -
?
Features
?
1. Real time detect ozone in wall mounting type
2. Semiconductor ozone gas sensor inside and measuring range 10~500ppb.
3. More than 5 years lifetime.
4. Special temperature compensation design for ozone measurements
5. Design an easy zero-calibration way
6. Full time indicates ozone levels with special design 6 indicator lights
7. Six different ozone range corresponds with different lights indicating.
8. The on/off output option for control an ozone generator
9. Four setting ozone level ranges can be selectable to control the relay output via jumpers
10. Optional one analog output for ozone measurement
11. Modbus RS-485 interface with 15KV antistatic protection, independent address setting.?
?
Models
?
- - - -
ITEM | MODEL | DESCRIPTION |
Ozone Detector/Controller | F2000TSM-O3-L100C | Ozone indicator with 6 LED indicator lights Modbus RS485 interface |
F2000TSM-O3-L101C | Ozone indicator with 6 LED indicator lights One dry contact output, Modbus RS485 interface |
F2000TSM-O3-L110C | Ozone indicator with 6 LED indicator lights One analog output, Modbus RS485 interface |
- - - -
?