Electrical Product Agents

Share us

Ozone Meter?/ O3 Sensor With 6 LED Lights And Modbus RS485 Interface

AIA-1

Description

Specifications
?

- - - -
Gas detected | Ozone |
Sensing element | Semiconductor ozone gas sensor |
Power Supply | 24VAC/VDC±10% |
Consumption | 2.2 W |
Temperature sensor | NTC |
Warm up time | 96 hours (first time)?? 1 hour(operation) |
Signal Update | 2s |
O3 Measuring Range | 10~500ppb |
O3 measuring precision | ±15ppb + 20% reading (15~35℃/30~60%RH) |
Six indicator lights | The first green indicator light:O3≤49ppb The first and the second green indicator lights:50ppb~99ppb The first yellow indicator light:100ppb~199ppb The first and the second yellow indicator lights:200ppb~299ppb The first red indicator light:300ppb~399ppb The first and the second indicator lights:O3 ≥400ppb |
Modbus interface | Modbus RS485 protocol with19200bps(default), 15KV antistatic protection, independent base address, 31 max network nodes |
Relay output(optional) | One dry contact output, rated switching current 2A(resistance load). Provide four ozone ranges to be selected to control the relay turn-on/turn-off ?(50ppb /100ppb-default / 200ppb/ 300ppb) |
Analog output(optional) | 1X0~10VDC or 4~20mA for ozone measurements |
Operation temperature | 5~50℃ (41~122℉) |
Operation humidity | 0~80%RH,non condensing |
Weight | 190g |
Dimensions | 100mm×80mm×28mm |
Installation standard | 65mm×65mm or 2”×4” wire box |
Housing/ IP rate | PC/ABS plastic fireproof material, IP30 |
Standard | CE-Approval EN60730-1:2000 +A1:2004 + A16:2007 + A2:2008 Directive: 2004/108/EC |
- - - -

?

Features

?

1. Real time detect ozone in wall mounting type

2. Semiconductor ozone gas sensor inside and measuring range 10~500ppb.

3. More than 5 years lifetime.

4. Special temperature compensation design for ozone measurements

5. Design an easy zero-calibration way

6. Full time indicates ozone levels with special design 6 indicator lights

7. Six different ozone range corresponds with different lights indicating.

8. The on/off output option for control an ozone generator

9. Four setting ozone level ranges can be selectable to control the relay output via jumpers

10. Optional one analog output for ozone measurement

11. Modbus RS-485 interface with 15KV antistatic protection, independent address setting.?

?

Models

?

- - - -
ITEM | MODEL | DESCRIPTION |
Ozone Detector/Controller | F2000TSM-O3-L100C | Ozone indicator with 6 LED indicator lights Modbus RS485 interface |
F2000TSM-O3-L101C | Ozone indicator with 6 LED indicator lights One dry contact output, Modbus RS485 interface |
F2000TSM-O3-L110C | Ozone indicator with 6 LED indicator lights One analog output, Modbus RS485 interface |
- - - -

?

Wiring Diagram

?



?

Dimension & Mounting

?

cheap prodocuts, china suppliers,

Read More

Previous

Home Co2 Monitor Wall Mounted Carbon Dioxide Detector ?With LCD Display...

Previous

Relay Output Digital Co2 Controller Grow Room 3 LED indicators...

Tongdy Control Technology Co., Ltd

CO2 Monitor,CO2 Controller,CO2 Transmitter

Address: Building #8, Courtyard #9, Dijin Rd., Haidian Dist., Beijing 100095, China,
Beijing, Beijing
China, 100095

Tel: 86-10-59738930
Fax: 86-10-59738935

H5响应式定制设计
26种语言,SEO营销型网站


H5/响应式/营销型企业网站; 26种语言扩展;
覆盖: 英文、法语、德语、西班牙语、葡萄牙语、俄语、阿拉伯语、波斯语、日语、韩语
了解更多