1KVA- 2KVA Smart Line Interactive Online UPS Uninterruptable Power Supply
?
Application:
Personal computer.Computer center.Data center.Network center.Other emergency equipment
?
?
Main Features:
?
?? MCU is adopted in the core technology, the use of DC/AC and AC/DC two-way transformation technology, provide the pure sine wave output.
?? The use of intelligent high-current two-stage charging technology, can effectively extend the life of the battery.
? It can change battery in case of uninterrupted power supply.Maintenance for battery is simple and reliable.
?? CPU intelligent centralized control technology, the UPS output voltage is more stable.It has perfect protection function, whether it is UPS overload, short circuit, low battery voltage, overheating, the system will protect automatically.
?? Standard RS232 communication interface. By monitoring software, you can debug and monitor remote online UPS operation directly. Simplify network management, and improve reliability of system.
? Can be used as a stand-alone SNMP network nodes, with monitoring software, network monitoring function come true.
?
Specification:
?
- - - -
MODEL | HT10 | HT10L | HT20 | HT20L |
Capacity | (VA) | 1000 | 2000 |
OUTPUT | ???Voltage | 220Vac±1%(battery?mode) |
Frequency | 50Hz±0.1Hz(battery?mode) |
???Waveform? | ????????Pure?sine?wave |
THD | <3% |
Power?factor | 0.7? |
INPUT | Frequency | 47Hz~53Hz(setting) |
Voltage | 168Vac-272Vac |
Standby?time | Full?load | 10minutes | Any?configuration | 10minutes | Any? configuration |
Half?load? | 25minutes | Any?configuration | 25minutes | Any? configuration |
BATTERY | Type | Sealed?lead?acid,?maintenance?free |
Nominal?voltage | 24Vdc | 48Vdc |
Efficiency | DC?TO?AC | >80% |
Noise | Distance | Full?load<50dB(A) |
Alarm?function | ? | Light?and?buzzer?alarm |
Automatic?Restart | ? | Auto?restart?when?AC?recovery? |
DC?Start | ? | √ |
Software?setting?????? open/close | Auto?Start-up | √ |
Protection | Overload? | Utility?mode:≥200%?for?3?second;??≥100%?for? 10minutes |
Battery?mode:≥150%?for?3second;≥100%?for ?60?seconds |
Over?Voltage/???
?low?Voltage | Latching?Inverter?Shut?down |
Short?circuit | Latching?Inverter?Shut?down |
Battery?discharge | output?will?be?automatically?closed |
EMC | ? | GB?9254 |
Communication?interface | RS232/LAN | Outage,low?battery?voltage,Remote?control?UPS?power ?off and?Real-time?monitoring?communication |
Environment | temperature | 0~40℃ |
temperature | 0-95%(without?condensing) |
?Mechanical?Data | Dimension????
(W×D×?H)mm | 150×445×220 | 150×445×220 |
Weigh(kg) | 18 | 13 | 26 | 16 |
- - - -
? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ??
?