Three Phase Rack Mount Smart Online UPS High Frequency 1KVA - 30KVA
?
Application range
?
Computer center, network center, data center, electronic medical equipment, industrial control equipment, and other emergency equipment
?
Performance feature
?
True online and double conversion design??
?Effectively reduce the pollution of the AC network, provide pure power and good protection to mainly load.
?
Advanced IGBT component
?
Highly effective and stable performance make sure the system running reliably and stability
?
With output isolation transformer
?
With Strong impact, can provide better protection for the interference caused by transient variation of the load
?
Intelligent digital battery control
?
# Config the best charge current basing on the capacity and spec of battery
# Choose the appropriate recharger for long backup system
# Temperature compensated function, automatically adjust the charging voltage according to the change of the ambient temperature, to improve the life of battery
?
Easy maintenance design
?
Display all the information and status of the unit
?
N+X redundancy and parallel technology
?
# High reliability
# No need for additional parallel configuration
# Parallel operation controlled by internal microprocessor
# Digital equal flow control technology to make the UPS highly compatible.
?
UPSLION2000 monitoring software
?
UPSilon2000 can detect all the information about UPS, including temp, capacity, load, voltage and so on. When AC fails or low battery, the UPS can be started and run automatically. UPSilon2000 fully support Windows95/98/ME/NT 4.0/2000/XP etc. Network monitoring enables the UPS to have the function of self-diagnosis by using SNMP adapter
?
?
Performance index
?
?
- - - -
Model | HQ10 L (P) | HQ20 L (P) | HQ30 L (P) | HQ50 L (P) | HQ60 L (P) | HQ1110 L (P) | HQ3110 L (P) | HQ3115 L (P) | HQ3120 L (P) | HQ3130 L (P) |
Capacity | (KVA) | 1 | 2 | 3 | 5 | 6 | 10 | 10 | 15 | 20 | 30 |
Output | Voltage | Single-phase 220Vac± 1% |
Frequency | Line mode: 50Hz±5%,Batter mode: 50Hz±0.5% |
Dynamic response | ±3%(100%load change) |
Wave distortion | <3% linear load |
Crest Factor | 3:1 |
non-balance degree of load current | ≤3%(specific to the UPS with parallel operation function) |
Input | Voltage | 165Vac-270Vac | 285Vac-475Vac |
Frequency | 45-65Hz |
Transfer time | Power off/reconnection | 0 |
Battery | Type | Sealed, maintenance free, Lead acid battery |
DC voltage | 192Vdc | 240Vdc |
Charge current | Depending on the needs |
Noise Level | 1m distance | <55dB(A) |
Display | LED | AC, Inverter, Low battery, Bypass, Overload, Failure |
LCD | Input/output voltage & frequency, battery voltage, load percentage, UPS status, temperature |
Protection | Alarm | LCD indicates voltage,frequency, battery,load,temp |
Protection | Battery low/Overload/Short-circuit/Overheat/Cold start function |
Overload | 125%,≥1min |
Output power factor | 0.8 |
Transfer time to bypass | 0ms |
Input frequency track | ≤1Hz/s |
Communication | Interface | RS232/Dry contact |
Environment | Temperature | 0~40℃ |
Humidity | 0- 95%(non-condensing) |
Options | ? | 1. SNMP adapter; 2. Parallel up to 8 modules |
Dimension | Width(mm) | 180 | 240 | 480 | 560 |
Depth(mm) | 498 | 580 | 426 | 720 |
Height(mm) | 366 | 554 | 885 | 1200 |
Weight(kg) | 25 | 30 | 35 | 65 | 70 | 120 | 125 | 150 | 180 | 240 |
- - - -
?