Computer Related Projects
Description
?
LCD Display 220Vac / 120Vac / 110Vac High Frequency Online UPS 6-10Kva
# DSP Technology:?The advanced DSP digital control technology enable UPS more stable performance.
# Environment Friendly:?This UPS is eco-designed and manufactured to meet the China local pollution control requirement of Electronic Products, which means it will cause no harm to environment and human beings in normal usage.?
# Active input power factor correction (PFC)
# Wide range of input voltage and frequency
# Zero power switch delay
# Active Load Management
# Sufficient Expansion Slots
Features:
# Pure on-line double conversion design
# Wide input range
# Flexible intelligent monitoring program and strong communications function
# Compact design
# Precise utility power synchronizing system
# Cold start function
# Perfect protection
# Power conservation UPS
# LCD man-machine conversation platform design
- - - -
CE Series LCD Display 220Vac / 120Vac / 110Vac High Frequency Online UPS CE6K CE6KS |
Model | CE6K | CE6KS | Comments |
Input |
Input voltage |
Rated voltage | 220VAC | |
Phase | Single phase with ground | |
Turn on voltage range | (120±5~274±5)VAC | |
Bypass voltage range | (60±5~300±5)VAC | Could be adjusted by software. |
Bypass low loss | 60VAC~220VAC(default 60VAC) |
Bypass low comeback | Low loss +5VAC |
Bypass high loss | 220VAC~300VAC(default 300VAC) |
Bypass high comeback | High loss -5VAC |
Line low loss/comeback | (120±5) VAC /(140±5) VAC | load≤50% |
(150±5) VAC /(165±5) VAC | 50%<load≤80% |
(160±5) VAC /(175±5) VAC | 80%<load |
Line high loss/comeback | (274±5)VAC/(260±5)VAC | |
Input frequency |
Rated frequency | 50Hz | |
Frequency low loss | (40~49) ±0.2Hz(default:46Hz) | Could be adjusted by software. |
Frequency low comeback | Frequency low loss +0.5Hz |
Frequency high loss | (51~60)±0.2Hz(default:54Hz) |
Frequency high comeback | Frequency high loss -0.5Hz |
Input power factor |
Input power factor | > 0.99 | 220VAC,full R load |
Generator? | Support generator input | Generator rating≥2*UPS rating |
Input current |
Rated current? | 25A | 27A | |
Input THDI | 10% | |
Output protection |
Rating protection | 32A Breaker | |
Output power |
VA/watt | 6000/4800 | |
Rated voltage | 220VAC | Sine wave |
Voltage range | 200/208/220/230/240VAC | Could be adjusted by software. 10% derating for 208VAC/200VAC. |
Voltage regulation | ±1% | |
Voltage distortion | ≤6% | Full RCD load |
≤2% | Full R load |
DC offset | ≤200mV | |
Transient response | ≤9% | R load 0%~100%~0% |
≤6% | R load 20%~100%~20% |
Transient recovery | ≤60ms voltage recovery to 90% | Full RCD load |
Bypass output before turn-on | YES | |
Crest ration | 3:01 | |
Output frequency range |
Normal mode | 1,Same as input frequency(46Hz~54Hz) | |
2,50Hz(Input frequency>54Hz or |
Input frequency<46Hz) |
Battery mode | (50+0.1) Hz | |
Slew rate | 1 Hz/Sec | |
Efficiency |
Normal? mode | > 90% | |
Battery mode | > 88% | |
Overload | Overload warning only | 105%±5%≤load |
Normal mode/battery mode? | 1min,then transfer to bypass and alarm. | 105%±5%
Automatically retransfer | YES | |
Short protection |
Normal/battery mode | YES | |
Transfer time |
Normal to battery mode | 0mS | |
Battery to normal mode | 0mS | |
Normal to bypass mode | <4mS | 0mS(option)with load |
Bypass to normal mode | <4mS | 0mS(option)with load |
Battery and charger |
Battery |
Rated voltage | 192VDC | |
Type/Rating | 7AH/12V | / | |
Battery quantity | 16 PCS | |
Backup time | > 14min? | Half load |
Protection |
Low alarm voltage / comeback voltage | (180.8V±4V)/ (188.8V±4V) | |
Shutdown voltage/ comeback voltage | (176V±4V)/ (184V±4V) | (176V±4V)/ (184V±4V)/ | Load < 1000W |
(152V±4V)/ (160V±4V)/ | (160V±4V)/ (168V±4V)/ | Load >= 1000W |
DC protection |
Overcharge protection/ comeback voltage | (249.6V±4V) / (216V±4V) | |
Leakage current | < 500uA | |
Over discharge protection | 14.5h | Could be set by software |
Battery test |
Battery weak | YES | |
Battery fault | YES | |
Charger |
Output voltage | (219.2±3)VDC | |
Charge time | 7 hours to 90% capacity | | |
Charge current | 1A | 5.5A | |
Interface |
Alarm silence | YES | |
DC power turn-on | YES | |
Automatically retransfer | YES | |
Audio alarm |
Battery mode | Beep/4s | |
Battery low/charger fault | Beep/1s | |
UPS fault | Continue beep | |
Overload | Beep/1s | |
Bypass mode | Beep/2Min | |
L/N inverse | Beep/2Min | |
Communication |
RS232 interface | YES | |
Intelligent slot | YES | |
Monitor software | Appending with UPS | |
Cooling |
Force air cooling |
Display |
LCD/LED displays UPS status |
Environment |
Work temperature | 0℃~40℃ | |
Altitude | <1000m | |
Audible noise | ≤55dB | |
Storage temperature | -15℃~45℃ | |
Work humidity | 20%~95% | |
Standard |
EMS |
ESD | IEC61000-4-2 | Level4 |
RS | IEC61000-4-3 | Level3 |
EFT | IEC61000-4-4 | Level4 |
Surge | IEC61000-4-5 | Level4 |
EMI |
Conducted | EN55022 | Class B |
Radiated | EN55022 | Class B |
Safety |
Safety | GB4943-2001/IEC62040-1 | |
Transportation |
Drop test | GB-T4857-18 | |
Vibration test | B-WR1-129(GB-T14715-93) | |
Machinery features |
Size |
Outline dimension and net weight |
L * W * H (mm) | 560*260*717 | 533*260*501 | |
Net weight(Kg) | 61.5 | 21 | |
|
Optional functions |
60Hz | | Set by software |
Converter mode | | Set by software |
ECO | Optional | Available and set by software |
EPO | Optional | |
LCD display | Optional | |
- - - -
?
?
?
Read More
Shenzhen Zhongyuan Chuangda Technology Co., Ltd
Low Frequency Online UPS,High Frequency Online UPS,Rack Mount UPS
Address: Bldg. 3, Meiran Workshop, Haogong Building, No. 2, Yannan Rd., Futian Dist., Shenzhen, Guangdong, China,
Shenzhen, Guangdong
China, 518000
Tel: 86-755-83265608
Fax: 86-755-83208560