Energy & Environment

Share us

Nitrogen Sample Concentration

No.1-1

Description

Product description:?NDK200-1/2 Nitrogen Sample Concentration is mainly used for enrichment of large-volume sample or preparation (such as drug screening, hormone analysis, liquid phase, and mass spectrometry in the analysis of sample preparation). Working principle: the nitrogen into the heated surface of the sample and make the solvent t evaporate and separated rapidly, thereby reaching the sample enrichment purpose without oxygen, keep the sample purer. Nitrogen concentrator instrument can concentrated dozens of samples simultaneously, saving time and high efficient, instead of rotary evaporation instrument.Product features1. Heater heat the sample in the bottom and nitrogen blow on the surface to accelerate liquid for ?evaporation and sample concentration.2. The position of gas needle in air cavity can be adjusted to suit for various tubes.3. The height of the air cavity can be adjusted. The length of a standard gas needle is?150mm.4. Gas needle is controlled independently. Separately blow of each needle and flow regulating of each needle are available to avoid gas waste.5. The entire unit can be working in ventilation cabinet when concentration poisonous sample.6. Built in overheat protection, automatic fault detection and fault beep alarm device.7. LED display immediate temperature and diminishing time. Operation is simple and convenient.8. Nitrogen sample evaporator configures air cavity and adjustable bracket.Technical ParametersModelNDK200-1NDK200-2Temp. Control RangeR.T.+5°C ~150°CR.T.+5°C ~150°CTemp. Setting range5°C ~150°C5°C ~150°CTemp. Stability@40~100℃≤±0.5°C≤±0.5°CTemp. Stability@100~150℃≤±1℃≤±1℃Block Temp. Uniformity@100°C≤±0.5°C≤±0.5°CBlock Temp. Uniformity@150°C≤±1 °C≤±1 °CDisplay Accuracy0.1°C0.1°CHeating Speed≤30min (40℃~150℃)≤30min (40℃~150℃)Time Range1min ~99h59min1min ~99h59minMax Stomatal plate?lift stroke285mm285mmGas Needle Joint DiameterΦ7mmΦ7mmNitrogen Pressure≤0.1MPa≤0.1MPaNitrogen Flow Rate0 ~10L/min0 ~10L/minGas Needle Length150mm150m

Nitrogen Sample Concentration, General Sample Concentration,

Read More

Previous

Rechargeable Handheld Homogenizer...

Previous

Heating Digital Dry Bath...

MIULAB Co., Ltd

Key Word

Address: 2F, Block 1, Deyu Building, 1418-3 Moganshan Road, Hangzhou, Zhejiang, China,
Hangzhou, Zhejiang
China, 310011

Tel: 86-571-87653906
Fax: 86-571-87653907

H5响应式定制设计
26种语言,SEO营销型网站


H5/响应式/营销型企业网站; 26种语言扩展;
覆盖: 英文、法语、德语、西班牙语、葡萄牙语、俄语、阿拉伯语、波斯语、日语、韩语
了解更多