Electrical & Hardware

Share us

Module Design High Frequency Online UPS 1600w 125% Overload

RST2K

Description

Module?Design?High?Frequency?Online?UPS 1600w?125%?Overload

?

?

Quick Detail:

?
# Module design
# Input:115-300Vac 40-60Hz/50-70Hz
# Output:220/230Vac(1±2%)
# Rated capacity :2KVA
# Input Power factor:0.99
# Output On-load factor:0.8

?

?

Specifications:

?

- - - -
MODEL | RST1K | RST1KS | RST2K | RST3K |
Rated capacity | 1KVA/800W | 2KVA/1600W | 3KVA/2400W |
Input | Voltage | 115 - 300Vac |
??Frequency | 40-60Hz / 50-70Hz |
Power factor | 0.99 |
Output | Voltage | 220/230Vac(1±2%) |
? Frequency | Synchronize with utility power(utility mode); 50/60Hz±0.2Hz(battery mode) |
On-load factor | 0.8 |
Overload rating ? | 125% overload,1min |
Battery | Type | Valve-control lead acid maintenance-free battery |
Back up time | more than 11min (half load) | External | External | External |
Rated voltage | 36V | 72V | 96V |
Transfer time | 0 |
Operating environment | Humidity:?20%-90%,?Temperature:0oC-40oC |
Size (WxDxH)mm | 610x600x270 | 610x600x270 | 610x600x270 |
Net Weight(kg) | 18 | 12 | 12 | 12 |
- - - -

?

?

Environment Friendly: This UPS is eco-designed and manufactured to meet the China local pollution control requirement of Electronic Products, which means it will cause no harm to environment and human beings in normal usage.

Active input power factor correction (PFC): Digitalized control of the PFC enable the UPS to keep input power factor above 0.99 to prevent possible electric grid pollution and meanwhile mostly save the cost.

Wide range of input voltage and frequency: We intentionally widen the range of input factors to make sure the UPS can apply to various environment, which will effectively sustain the battery charging even in unstable power environment so that the service life of the UPS could be obviously prolonged.

Zero power switch delay: When the utility power fails, UPS will automatically switch from AC mode to battery mode with no delay, which ensures stable power supply of operating system.

Active Load Management: This technology allows the UPS to be set up at a fixed 50Hz or 60Hz output, while it also can intelligently monitor power usage and automatically sheds and reconnects loads in order to prevent generator overload.

?

?

cheap prodocuts, china suppliers,

Read More

Previous

6KVA High Frequency Online UPS 30KG Valve-Control Lead Acid Maintenance-Free Battery...

Previous

36V High Frequency Online UPS 800W 350mm...

Shenzhen Ada Power Electronics Co.,Limited

Low Voltage Variable Frequency Drive,Solar Variable Frequency Drive,3 Phase Variable Frequency Drive

Address: Xinzhong Road Baishi Zhou Nanshan District,
Shenzhen, Guangdong
China, 518000

Tel: 86-755-86099322
Fax: 86-755-86099322

H5响应式定制设计
26种语言,SEO营销型网站


H5/响应式/营销型企业网站; 26种语言扩展;
覆盖: 英文、法语、德语、西班牙语、葡萄牙语、俄语、阿拉伯语、波斯语、日语、韩语
了解更多