Batteries & Chargers
Description
?
Single?Phase?High?Frequency?Online?UPS?240V?36VDC
?
?
Quick Detail:
?
# Rate Capacity:1K-3KVA
# Power factor:0.8
# Input:(90±5)VAC~?(300±5)VAC
# Output:220Vac
# Input?system:Single?phase?&?earth?ground
# Voltage?precision:±2%
?
?
?
Specifications:
?
- - - -
MODEL | VT1K | VT1KS | VT2K | VT2KS | VT3K | VT3KS |
Rating | 1KVA/800W | 2KVA/1600W | 3KVA/2400W |
Input | Input?system | Single?phase?&?earth?ground |
Voltage?range | (90±5)VAC~?(300±5)VAC |
Power?factor | ≥0.99 |
Voltage?range?of?bypass | (80±5)VAC~?(286±5)VAC?(default:?80VAC~264VAC? Could?be?adjusted?by?software) |
Output | Output?system | Single?phase?&?earth?ground |
Rated?voltage | 220VAC??① |
Power?factor | 0.8 |
Voltage?precision | ±2% |
Output? frequency | Normal?mode | 1.The?output?frequency?synchronizes?with?the?input?frequency? when?the?input?frequency?is?in?the?range?of??46?Hz~?54?Hz 2.The?output?frequency?is?50Hz?when?the?inpu t?frequency?is?not?in?the?range?of?46?Hz~?54?Hz 3.Can?be?set?as?60Hz |
Battery?mode |
Inverter?overload? capacity?(Utility?power,?25℃) | 105%±5%
Transfer?time | 0ms?(Normal?mode←→?Battery?mode) |
<4ms?(Normal?mode←→Bypass?mode) |
Crest?factor | 3:1 |
Battery | Batteries?voltage | 36VDC | 72VDC/96VDC | 96VDC/72VDC |
Battery?quantity | 3 | None | 6/8 | None | 8/6 | None |
Battery?Type | Sealed?maintenance-free?lead?–acid?battery?of?battery?voltage?12V/7AH |
Backup?Time?(25℃) | Full?load≥5min?(Standard) |
Charge?current | 1A | 6.5A | 1A | 5.5A | 1A | 5.5A |
①?Note1:?Output?voltage?can?be?set:?200V/208V/220V/230V/240V. |
- - - -
?
?
?
Active input power factor correction (PFC): Digitalized control of the PFC enable the UPS to keep input power factor above 0.99 to prevent possible electric grid pollution and meanwhile mostly save the cost.
Wide range of input voltage and frequency: We intentionally widen the range of input factors to make sure the UPS can apply to various environment, which will effectively sustain the battery charging even in unstable power environment so that the service life of the UPS could be obviously prolonged.
Zero power switch delay: When the utility power fails, UPS will automatically switch from AC mode to battery mode with no delay, which ensures stable power supply of operating system.
Active Load Management: This technology allows the UPS to be set up at a fixed 50Hz or 60Hz output, while it also can intelligently monitor power usage and automatically sheds and reconnects loads in order to prevent generator overload.
Sufficient Expansion Slots: The pre-allocated smart slots enable flexibility in choice of USB cards,AS400 cards, CMC monitoring cards, SNMP cards, RS485 cards and EMD environment monitoring cards.
?
?