Generators
Description
CE off grid Solar Inverter Online DC12v AC 220v/230v 500w 1000W solar inverter efficiency rate 93%
?
Model :?LI-50112
?
Multifunctional operating interface:
?
?
a. Adjustable mains priority and inverter priority mode:
Mains priority: When AC mains and DC battery are connected at the same time, inverter chooses AC mains for priority AC output.
b. Inverter priority: When AC mains and DC battery are connected at the same time, inverter converts DC battery power for priority AC output.
Customers can choose mains priority or inverter priority mode according to their own needs, and can switch them at any time.
?
Switching power is supplied by independent system
It uses a separate power for a single switch chip, which reduces the interference of pulse and make inverter works stably.
?
Full-bridge rectifier and PCB structure is highly optimized. Input and output circuits are truly isolated.
PCB is highly optimized, which is insulated and isolated by modularization. Full-bridge front-end circuit rectifies and provides outputs, back-end circuit transformer controlled by intelligent program. Input and output circuits are truly isolated. And model number, production date and batch are printed on the PCB for tracking.
?
?
- - - -
Model | LI-351 | LI-501 | LI-601 | LI-102 | LI-152 | LI-202 | LI-302 | LI-502 | LI-702 | LI-103 | LI-153 | LI-203 |
Rated Power | 350W | 500W | 600W | 1KW | 1.5KW | 2KW | 3KW | 5KW | 7KW | 10KW | 15KW | 20KW |
Peak Power | 700W | 1000W | 1200W | 2KW | 3KW | 4KW | 6KW | 10KW | 14KW | 20KW | 30KW | 40KW |
Nominal battery voltage | 12VDC | 12VDC/24VDC | 24VDC/48VDC | 48VDC | 96VDC | 192VDC |
Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) / 84-120VDC (96V) / 168-240VDC (192V) |
AC Mains input range | (220/230/240VAC) 140-275VAC | 170-250VAC |
AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz (50Hz/60Hz automatic recognition) |
Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) / ≤84VDC (96V) / ≤168VDC (192V) alarm |
Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) / ≤80VDC (96V) / ≤160VDC (192V) automatic shutdown |
High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) / ≥120VDC (96V) / ≥240VDC (192V) alarm |
High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) / ≥136VDC (96V) / ≥272VDC (192V) automatic shutdown |
Over load protection | 110% more than rated capacity, automatic shutdown |
High temperature | Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown |
Short circuit protection | Automatic shutdown |
Output | Transfer efficiency | ≥85% |
Output voltage | (DC battery mode) 220/230/240VAC±2% |
Output frequency | (DC battery mode) 60/50Hz±1% |
Output wave form | Pure sine wave |
Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) |
AVR output stablizer | AC mains<140VAC±5% swtich to DC battery mode, AC mains>150VAC ±5% return to AC mains mode; |
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; |
The above is for output 220V system reference, 230V/240V output just multiply by percentage |
Output frequency | (AC mains mode) automatic tracing from AC input |
Other | Transfer time | ≤10ms |
Display | LCD Display with function buttons |
Cooling system | Intelligent cooling fan control system |
≤42℃ slow fan, ≥45℃ fast fan |
AC Charger | AC charging Voltage | 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V)/108.8-113.6VDC(96V)/217.6-227.2VDC(192V) |
AC charging current | Steady 15A |
AC over charge protection | Battery ≧16V (12V) ≧32V (24V) ≧64V (48V) ≧128V (96V) ≧256V (192V), stop charging after 60s alarm |
Working mode
(Optional) | 01 | AC mains priority |
Always use AC mains as priority input to provide AC output and automatically charge the battery, |
only stops charging when battery is fully charged, and only starts DC to AC converting untill AC mains is off |
02 | Energy saving |
Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on |
03 | DC battery priority |
Always use DC battery as priority input to provide AC output, for 12V system, when battery≥13V, starts DC to |
AC converting; when battery≤10.5V during converting, switch to AC mains mode to provide AC output and |
automatically start charging the battery (for 24V/48V/96V/192V system, multiply by 2/4/8/16 accordingly) |
Comnunication | RS-232/USB/SNMP(additional option) |
Environment | Temperature | -20~75℃ |
Humidity | <95% |
Appearance | Product size (mm) | 300*240*120 | 410*225*410 | 485*300*655 |
Packing size (mm) | | | |
Net Weight (kg) | 7.2 | 7.5 | 7.5 | 8.7 | 23.5 | 25.5 | 28.8 | 55 | 56 | 85 | 105 | 125 |
Gross Weight (kg) | | | | | | | | | | | | |
*Product specifications are subject to change without further notice |
- - - -
?
Our Services
1. Sample Services
Applicable to quality test, function test, etc.
2. Repair Services
One year warranty
3. Perfect after sales service system
If any problem, contact us.
4. ODM Services
Powerful R&D department can provide
professional technical support.
5. OEM Services
More than 100 pieces, you can decide the
trademark and package.
6. Quality utmost
Each product reaches the national
standard before factory inspection.
?
?
Read More
Foshan Top One Power Technology Co., Ltd
Solar Powered Inverter,Pure Sine Wave Inverter,MPPT Solar Inverter
Address: 5F, Bldg.2,,No.117 Zhangchayi Road,
Guangzhou, Guangdong
China, 510000
Tel: +86-757-82589781
Fax: 86-757-82589791