Single & Three Phase Meter Test Equipment

KE8301S

Description

# # Test both three phase open link meter and single phase meter
# Accuracy Class:? 0.05%
# Meter position: 6 / 12 / 24 / 48 position
# Name: Energy meter test equipment, electric meter test bench
# Power: Electronic
# Voltage Output: 3×(24V – 300V)
# Current Output:? 3×(1mA – 120A)
# Operating Temperature: -10°C -- +40°C


?

Single & Three Phase Meter Test Equipment, Energy Meter Test Calibration Bench

?
Highlight: # Integrated/separated aluminum alloy structure, light and reliable, flexible choices
# Meter positions can be chosen from 6-48
# Auto protection of short circuit of voltage, open circuit of current, and overload.
# Test of neutral current (optional)
# Auto mark locking increases the efficiency of test
# Full automatic, semi automatic and manual operation available
# Supporting bar code input, which increase the efficiency of input
# Simultaneous test of the meters with same specification, different constants and different classes.
# Adopt multi-serial port system, realizing the parallel communication of computer and the tested meters( optional)
# Test of tilt impact (optional)
# Forward and reverse active energy/ Forward and reverse reactive energy error test
# Creeping and starting test
# Standard deviation, 24 hour variation test
# Timing error test
# Influencing quantity test of voltage, frequency, harmonic
# Calibration and verification of constant
# Register indicating value, register combination error test
# Powerful computer management system, easy and user-friendly
# Perfect database management makes the storage, searching, and viewing of the data possible, and the data can be converted and exported in other forms

?

KE8301S is used for the test of three phase four wire (3P4W) and three phase three wire (3P3W) electrical and mechanical meters, multi-function meters, smart meters, and multi-user meters of electric power company, meter manufacturing company and institutes of metrology, it can also do the test and calibration of single phase energy meters

?

?
Main specifications:
?

- - - -
? | KE8301S-6 | KE8301S-12 | KE8301S-24 | KE8301S-48 |
Number of meter position | 6 | 12 | 24 | 48 |
Accuracy | ± 0.05% |
Voltage output |
Output range (P-N) | 3×(24V – 300V) |
Output power of voltage | 3×100VA | 3×250VA | 3×500VA | 3×1000VA |
Resolution | Better than ± 0.01% |
Stability | Better than ± 0.02% / 150s |
Load regulation rate | Better than ± 0.01% |
Distortion factor | Better than ± 0.3% (linear resistance load) |
Harmonics output | 2nd -21st free programmable |
Current output |
Output range | 1mA – 120A (or customized,Max. 230A) | 3×(1mA – 120A) |
Output power of current | 3×150VA | 3×350VA | 3×750VA | 3×1500VA |
Resolution | Better than ± 0.01% |
Stability | Better than ± 0.02% / 150s |
Load regulation rate | Better than ± 0.01% |
Distortion factor | Better than ?± 0.3% (linear resistance load) |
Harmonics output | 2nd -21st free programmable |
Phase output |
Output range | 0 -- 360° |
Resolution | ± 0.01° |
Frequency output |
Output range | 45Hz – 65Hz |
Resolution | ± 0.01Hz |
Operation conditions |
Power supply | 3×220/380V±10% ,50/60Hz±2Hz |
Temperature | -10°C -- +40°C |
Humidity | 35% -- 85%RH |
- - - -

?

cheap prodocuts, china suppliers,

Read More

Previous

Single & Three Phase Meter Test Equipment...

Previous

Portable Electric Meter Test Bench Power Source Single Phase...

Guangzhou Kingrise Enterprises Co., Ltd

Energy Meter Test Bench

Address: Rm 210, No 69 Guangpu Rd(W), Luogang Dist,
Guangzhou, Guangdong
China, 510000

Tel: 86-020-62220181
Fax: 86-020-62220182

H5响应式定制设计
26种语言,SEO营销型网站


H5/响应式/营销型企业网站; 26种语言扩展;
覆盖: 英文、法语、德语、西班牙语、葡萄牙语、俄语、阿拉伯语、波斯语、日语、韩语
了解更多