24 positions Three Phase Electric Energy Meter Testing Equipment within Accuracy Class 0.02
YC893D - F - 24
Description
Description:
1)??? The meter test system can measure mechanical meter, electronic mechanical meters and ? ? ? ? ? ? ? ? ? ? ? electronic meter by ways of automatic, semi-automatic or manual operation.
?
2)??? Meters under testing: 3P4W, 3P3W, 1P2W.
?
3)??? Testing mode: active power, reactive power, cross connected reactive power.
?
4)??? Simultaneously measure meters with same specifications but different meter constants.
?
5)??? Automatic positioning rotor mark of disc of mechanical meter, with more efficiency.
?
6)??? Starting test and creeping test.
?
7)??? Neutral current test (optional).
?
8)??? Installing the ICT in each meter position to test three-phase meters with closed links between the ? ? ? ? ?current and voltage measuring circuits(I-P links)(optional).
?
9)??? With the protection function of overload, short voltage circuit and open current circuit.
?
10) ?The swing together of the scanning heads simplifies the control.
?
11) ?Aluminum alloy material, light and strong and corrosion resistant.
?
12) ?The testing software with friendly Windows 2000 /XP /7 /8 /10 operation system, includes ? ? ? ? ? ? ? ? ? ? ? functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, ? ? ? ? demand test, influence test etc,.
?
Specifications:
?
- - - -
Technical spec. | ? |
Number of meter positions | 24 |
Accuracy | 0.05 / 0.02 |
Power Source | YCS-103-1200 |
Standard Meter | SZ03A-K6 / SZ03A-K8 / Radian RD-33 |
Scanning Head | YCG-S Series |
Voltage | ? |
Test voltage output(Phase-Neutral) | 3* (24V~288V)(or customized) |
Power of the voltage output | Max. 3x500VA |
Resolution | Better than 0.01% of full scale value of range |
Setting accuracy | Better than 0.05% at the final range value |
Stability | Better than 0.005% /h (integration time 150s) |
Load regulation from 0~max. load | Better than 0.01% |
Distortion factor | Better than 0.3% for linear resistance load |
Harmonic | 2nd~21st??free programmable |
Current | ? |
Test current output | 3* (1mA - 100A) |
Power of the current output | Max. 3x750VA |
Resolution | Better than 0.01% of full scale value of range |
Setting accuracy | Better than 0.05% at the final range value |
Stability | Better than 0.005% /h (integration time 150s) |
Load regulation from 0~max. load | Better than 0.01% |
Distortion factor | Better than 0.3% for linear resistance load |
Harmonic | 2nd~21st??free programmable |
Phase angle | ? |
Range | 0~360? |
Resolution | 0.01? |
Setting accuracy | 0.1? |
Frequency | ? |
Range | 45Hz~65Hz |
Resolution | 0.01Hz |
Error display | ? |
Type of error display | Red LED |
Resolution of error displays | 8 digitals |
Other | ? |
Voltage supply | 3x220/380V±10%(or customized) 50/60Hz ±2Hz |
Ambient temperature | -10°C~+40°C |
Relative humidity | 35%~85% |
- - - -
?
?
?
Applications: # Nation-level utility companies
# Governmental bureaus of metrology
# Big energy meter manufacturers
Primary Competitive Advantages: # High quality product
# Over 18 months long warranty
# High accuracy class: 0.05/0.02
# Can be customized of Three Phase Electric Energy Meter Test bench
# Extremely high power stability
# Neutral current test(optional)
# Timing error test
# Influence test of voltage, frequency, and harmonic
# Installing RS232, Ethernet communication port in each meter position.
# Tilt impact test (optional)??
GENY& acute;s Test Bench in Landis+Gry & acute;s factory
?
Read More
Guangzhou GENY Electric Company
Meter Testing Equipment,Electric Meter Test Equipment,Portable Meter Test Equipment
Address: 3/F, Building C2, Kemulang Industry Zone,
Guangzhou, Guangdong
China, 510000
Tel: 86-20-87036713
Fax: 86-20-87037211