Perfume & Fragrances

Share us

ACLS Intelligent Child First Aid Manikins for Hospitals , Colleges Training

AIA-1

Description

?
ACLS Intelligent Child First Aid Manikins for Hospitals , Colleges Training

?

?
Specifications:

- - - -
1. Material: | Imported PVC |
2. Age: | Five-year-old,?One-year-old |
3. Logo: | General?Doctor? |
4. Product?Name: | Child First Aid Training Manikin |
5. Warranty?Period: | 1?Year |
6. Usage: | Colleges Researching ?for Child CPR Simulation |
7. Type: | Child Manikin |
8. OEM?Accepted: | Yes |
9.?Certificate?Available: | ISO?9001-2000? |
- - - -

?
?
Description:?
GD/ACLS1600 is designed according to experts experience and advice in the first-aid field and in accordance with five-year-old child anatomical characteristic. Complying with AHA (American Heart Association) 2005 emergency guideline for CPR and ECC, GD/ACLS1600 provides abundant real first-aid scenes for emergency physicians to train first aid operation process via friendly man-machine interface. The product is made of imported material with soft, elastic and not easily deformed skin, which is a good helper for pediatric teaching. It is the world leading man-machine interaction child ACLS training simulation system, can simulate real emergency scenes and all the related signs of emergency patient, such as: pupil states, artery pulse, heart rhythm, heart and lung auscultation sound, etc.

?

?
Features:
?

Head and Neck:

1. Pupil observation, one side is normal, the other side is dilated; the Flash animation displays light reaction and diameter changes of pupils;

2. Simulate airway foreign obstruction: foreign body obstruction in pharynx, main airway obstruction;

3. Carotid artery is available for five-year old child;

4. Respiration mode:Normalbreath, oligopnea, tachypnea, superficial respiration, excessive respiration, Kussmaul’s respiration, Cheyne-stokes respiration, meningitic breathing, sighing breath, irregular gasping, breathing holding;????

5. Voice: including crying, laughing, moaning, coughing, gasping and all kinds of complaints, etc;

6. Airway management: realistic mouth, nose, tongue, gum, throat, esophagus, epiglottis, trachea (the diameter of the simulative airway:?9mm); can practice tracheal intubation via mouth, sputum suction; simulate airway foreign body obstruction conditions(pharyngeal and main airway obstruction); can practice tracheal incision; only right lung ventilation due to excessive intubation position.

?

Chest and Abdomen:

1. Manikin organs include: bilateral lungs, stomach, bladder, rectum, bilateral lungs ventilation, liquid can be infused and drained out from bladder and rectum;?

2. Simulate spontaneous breathing, chest rise; can perform bilateral, left side , right side chest rise;

3. Bilateral puncture decompression and puncture effusion can be performed;

4. Femoral artery pulse

5. Auscultatory sound: including heart sound, respiratory sound, bowel sound; and the normal heart sound and respiratory sound can be adjusted according to the heart rate and respiratory frequency;

6. Gastric intubation: can perform gastric lavage, gastrointestinal decompression operation; intubation position can be detected via abdominal auscultation; suction of gastric liquid indicates successful intubation;?

7. Vital signs monitor: ECG, heart rate, respiratory frequency, BP, body temperature, saturation of blood oxygen, end-tidal partial pressure of CO2, etc; the flash can simulate spasm condition;?

8. Simulate skin color: normal, central cyanosis, peripheral cyanosis, mixed cyanosis, pale;

9. Urethral catheterization: can change male/female perineum to practice male/female catheterization;

10. CPR: Support multiple ventilation ways: mouth to mouth, mouth to nose, BVM to mouth; electronic monitoring of airway open, inflation times, frequency, volume and compression times, frequency, position and depth; automatic judgment of artificial respiration and chest compression ratio; English voice prompts during the entire process;

11.?AED, defibrillation and pacing: multimedia animation displays AED and defibrillation process;

1.Real defibrillation and pacing: Achieve real defibrillation and pacing by using with real defibrillating pacer(prepared by user-self);

2. ECG monitoring: Be used with real ECG monitor (prepared by user-self) to realize ECG monitoring,Simulative ECG monitoring should be used with GD/J115 multi-parameter simulation of ECG to achieve the function of monitoring ECG.

3. Simulate defibrillation and pacing: should be used with GD/J880; can choose defibrillation energy, the max energy is 360J;

4. Simulate AED: be used with GD/AED99Fto simulate AED operation; English voice prompts during the entire process; providing electrode button; automatic heart rhythm detection and analyze if the defibrillation is needed.

?

Limbs:

1. Manual BP measuring arm can simulate BP measurement with Korotkff sound;

2. Venous puncture/transfusion: arm vein, femoral vein, dorsal vein of foot

3. Skin care

4. Intramuscular injection: bilateral deltoid , bilateral vastus lateralis;

5. Bone marrow puncture: tibia with obvious body surface symbol, effusion of simulative bone marrow indicates proper puncture operation;

?

Software:

1. Provide various kinds of drug and multiple administration ways: i.v. drops, i.v., hypo., intramuscular injection, anal plug, injection pump, transfusion pump, etc; general dose and usage of each drug is preset; some drugs exist pharmacodynamic physiological reaction;?

2. Provide all kinds of auxiliary examination: biochemical report, CT, ultrasound, ECG, etc;

3. Training and examination, ECG identification training, CPR training and examination are available in the system;

4. Simulative cases training and assessment: Provide various clinical cases script

5. Perform PETCO2:? confirm tracheal intubation position and monitor the effectiveness of resuscitation operatio

?

?

Standard Component:

?

GD/ACLS1600A?Standard Components:
1. Intelligent ACLS Five-year-old Child Manikin

2. GD/HS7 BP Training Equipment

3. Heart and Lung Auscultation Simulator Set

4. GD/XD1000CECG Generator

5. GD/CC999CDefibrillator Converter

6. BVM, Stethoscope, Laryngoscope, Tracheotomy tube, Infusion set.

7. Emergency System Controller

8. Medical Air Compressor

?

GD/ACLS1600B Standard Components:

1. Intelligent ACLS One-year-old Child Manikin

2. GD/HS7 BP Training Equipment??????

3. Heart and Lung Auscultation Simulator Set

4. GD/XD1000CECG Generator

5. GD/CC999CDefibrillator Converter

6. BVM, Stethoscope, Laryngoscope, Tracheotomy tube, Infusion set.

7. Emergency System Controller

8. Medical Air Compressor

?

?

Pictures Show:

cheap prodocuts, china suppliers,

Read More

Previous

ECG Adult First Aid Manikins with ACLS Computer Screen for Colleges Training...

Previous

Intelligent ACLS Baby First Aid Manikins with BVM for Hospitals , Colleges Training...

Shanghai Honglian Medical Tech Group

First Aid Manikins,Clinical Simulation,Nursing Manikin

Address: 5th Floor, No.1 Bldg, Aijia International Bldg,
Shanghai, Shanghai
China, 200000

Tel: 86-021-55964925
Fax: 86-021-65223810

H5响应式定制设计
26种语言,SEO营销型网站


H5/响应式/营销型企业网站; 26种语言扩展;
覆盖: 英文、法语、德语、西班牙语、葡萄牙语、俄语、阿拉伯语、波斯语、日语、韩语
了解更多