Others
Description
?
50HZ Coal Mine Explosion Proof Transformer Insulation For 6 kva
?
?
Description:
?
Arc furnaces used in research laboratories and by dentists may have a capacity of only a few dozen grams. Industrial electric arc furnace temperatures can be up to 1,800 °C (3,272 °F), while laboratory units can exceed 3,000 °C (5,432 °F). Arc furnaces differ from induction furnaces in that the charge material is directly exposed to an electric arc, and the current in the furnace terminals passes through the charged material.
Mine use explosion proof dry-type transformer suitable for underground mines containing methane mixture gas and having potential danger of coal dust explosion. The transformers were be worked as the distribution equipment for a large variety of electrical equipment, like pumping station, conveyor, mining machine and so on. The transformer suitable for used in coal mine, non ferrous metal mine and tunneling.
?
?
Product standard
?
GB8286-2005????? Mine use explosion proof mobile substation
GB3836.1-2000 ???Electrical Apparatus for Explosive Gas Atmosphere—Part 1: General
GB3836.2-2000??? Electrical Apparatus for Explosive Gas Atmosphere—Part 2: Flameproof enclosure “d”
GB3836.3-2000???? Electrical Apparatus for Explosive Gas Atmosphere—Part 3: Increased safety “e”
JB4262-92??????? Rubber cable introduced for explosion proof electrical equipment
?
?
Applicable circumstances
?
The altitude is less than 1000M
The maximum temperature : 40 ℃,??? The minimum temperature : -5 ℃,
Relative humidity less than 95%( 25 ℃)
Underground mines containing methane mixture gas and having potential danger of coal dust explosion
No strong bump and vibrate, the vertical surface less than 15 degrees
There is no the gas and steam that could corrosive meter or damage the insulation in the environment
No leakage
The waveform of power is similar to sinusoidal wave
Three-phase voltage approximate to symmetrical
?
?
Competitive Advantage:
?
1. The transformer is mine use explosion proof type and has excellent explosion proof performance and mechanical strength.
2. Special design for inner construction, in case of inner construction was loosened in the term of delivery.
3.? The transformer has the strong capable of withstand thermal shock. It be able to overload and has the ability to withstand short circuit, low loss, a small amount of partial discharge and good insulation.
4. It is insensitivity to temperature and dust.
5. All insulation materials doesn’t combustion-supporting, self-extinguishing, non-toxic, excellent performance of fireproof, the transformer owned the characteristics like no harmful gases, low noise and no pollution.
6. it’s easy to use and maintain
7. Adopt C level of Nomex paper-covered wire from DuPont USA, it owned such features as air insulation, cooling, non-pollution, long lifetime and can be recycled.
8. Adopt the high quality 30Q130, 27Q120 cold rolling silicon steel and oxygen free copper conductor, the actual total loss is lower than similar foreign products, energy conservation and noise reduction.
?
?
Specifications: Main technical parameters
- - - -
Rated capacity | Primary rated voltage 6KV | ?????? primary rated voltage 10KV |
load loss | No-load loss | Short-circuit impedance | No-load current | Load loss | No-load loss | Short-circuit impedance | No-load current |
50 | 550 | 350 | ? 4 | ? 2.5 | 680 | 390 | ? 4 | ? 2.5 |
100 | 920 | 520 | 1050 | 560 |
125 | 1080 | 600 | 1300 | 650 |
- - - -
?
?
Common Size and capacity
?
1. Model
- - - -
Rated capacity | Phase | Frequency | cooing | Withstand voltage level | ?????? ?Voltage | symbol |
primary | taping | second |
50 | 3 | 50 | ANAN | H | 6000, 10000 | ±5 | 693/ 400, 1200/ 693 | Yy0 (d11) |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 | 1200, 3450 | Yy0, Yyn0, Dyn11 |
1600 |
2000 | C |
2500 |
3150 |
4000 | 3450 | Dyn11 |
- - - -
?
?