Flame Atomic Absorption Spectrophotometer for Laboratory , Photometer

AA-1800

Description

Flame Atomic Absorption Spectrophotometer for Laboratory , Photometer

?

?

?

Specifications:

- - - -
Mainframe |
Model: | AA-1800 |
Light Source: | ≤6 lamps automatic turret, automatic alignment |
Power Supply: | 110/220V (+5% ~ -10%), 60/50Hz; 5000VA |
Lamp Current: | pulsed power supply |
Optical System: | large 1800 /mm grating ruling, full closed optical system |
Wavelength Range: | 180nm-900nm????????????????? |
Automatically peak find,a key opticaloptimization function |
Wavelength Accuracy: | ≤0.15nm |
Wavelength Repeatability: | ±0.1nm |
Spectral Bandwidth: | 0nm,0.2nm,0.4nm,1.0nm,2.0nm |
(5 steps with automatic changeover) |
Baseline Stability: | ≤±0.002A/30 min (Static)????? |
≤±0.005A/30min (Dynamic) |
Absorbance Range: | 0-4A |
Detector: | imported photomultiplier?tube |
Flame Analytical System |
Burner Head: | full titanium?combustion head,?50mm or?100mm generalcombustion head |
Atomization Chamber: | polymer?explosion-proof?spray chamber |
Nebulizer: | atomizer?efficient?glass atomizer,?can also be customized |
Ignition Type: | microcomputer control,?automatic ignition |
Gas Control: | automatic?gas control system |
Detection Limits(Cu): | 0.002μg/mL |
Precision: | RSD≤0.5% |
Graphite Furnace Analytical System |
Heating Mode: | vertical?heating |
Temperature Control Method: | vertical optical?temperature monitoring?graphite tube?wall temperature |
Temperature Range: | room temperature to 3000℃ |
The Program: | automatic?temperature control?up to 20?order |
Temperature Control: | the furnace?enriched?up to 20 times |
Characteristics Volume: | 0.5 × 10-12g?(Cd) |
Detection Limit: | 0.4 × 10-12g (Cd) |
Precision: | RSD≤3% |
The Cooling Water: | can choose?cooling water circulation system |
Safety: | the?graphite?tube damage,?water flow |
air pressure and other?alarmtemperature?overheating protection |
Autosampler Graphite Furnace |
Sample Tray: | 70?sample cups,?6?reagent cup |
Sample Volume: | 1-100μl |
The Smallest?Lincrement: | 0.1 μl |
The Volume of Sample | better than 1%(at the time of 10mL-100mL) |
Repeatability?Volume |
Repeated?Sampling?Frequency: | up to 99 Times |
Cleaning and?Waste | each 500mL |
Container?Volume |
- - - -

?

?

?

Description:

?

AA-1800 atomic absorption spectrophotometer is absorted the latest international technology and famous

universities jointly complete R & D, application experience with decades of spectral instrument. The

products include the flame , graphite furnace and hydride generation system, can be equipped with

various accessories, flexible configuration program can meet different customer demand. AA-1800

atomic absorption spectrometer can be used for analysis of complex samples ,full automatic

multifunctional, various analysis methods can automatically switch, unmanned automatic analysis

?

Applications:

?

AA-1800 atomic absorption spectrophotometer is now widely used in scientific research,quality control,

disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and

software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples,

equipment maintenance, simple and convenient

?

Competitive Advantage:

?

High precision automatic optical system

● 1800 / mm reticle (dispersion rate) large area grating monochromator, a new type self collimation, all

lenses are quartz coating, the detection range and the stability of optical broad to ensure the precision of

analysis. Automatic 6 socket configuration six independent lamp power supply, can be respectively

preheating

Polymer spray chamber

● Polymer materials corrosion spray chamber, acid and alkali resistance, includinghydrofluoric acid, either

organic or inorganic solution can be the highest sensitivity andstability

Titanium burner

● Titanium burner, the optional 50mm and 100mm burner, air cooling pre mixed type,corrosion resistant,

resistant to high salt, greatly improve the analysis efficiency andaccuracy of the flame

Automatic analysis

● It can automatically accomplish safety ignition, extinction and switching, reliable structure,low fault rate, thus ensuring the sensitivity and reproducibility of the flame method.

● The light source system six lamp automatic conversion, can be directly used high performance hollow

cathode lamp, improve the sensitivity analysis of the flame, the automatic adjustment of the power supply

parameters and the beam position, automaticwavelength scanning and searching peak

Software function

● High intelligent software, powerful function, friendly interface English operation.Automatic instruments

and additional control, flame, graphite furnace operating mode can be switched automatically, automatic

optimization, automatic dilution; mouse operation, automatic setup menu data and correction method

Graphite furnace temperature control

● Gas dual temperature control inside and outside, 20 order linear or nonlinear heating, to ensure that

the measured elements has the highest sensitivity; furnaceenriched up to 20 times, the longitudinal

optically monitoring the graphite tube wall temperature, maximum temperature to 3000 degrees centigrade

High technology index

● AA-1800 atomic absorption spectrophotometer elements testsensitivity meet international best

level,sensitivity of less than or equal to0.015μg/mL/1%; baseline drift is less than 0.003Abs/30m, the

stability is better than 0.005Abs/4h

Background correction system

● Using deuterium hollow cathode lamp advanced and self absorption background deduction of

background correction, to eliminate the interference of molecular absorption of low content determination,

reducing the noise emission of deuterium lampand prolongs the service life, has excellent stability.

Deuterium lamp background signalfor 1A, background correction ability > 50 times

Intelligent analysis

● Greart intelligence, humanized design, flame and graphite furnace atomizer automatic switching,

automatic optimization of graphite furnace atomizer, automatically set the flame height adjustment,

automatic ignition, automatic optimization of the horizontal position, system automatically sets the gas flow.

In the case of power failure, misoperation, acetylene leakage, the system will automatically start the

safetyprotection function

Automatic sampler

● Integrative design of graphite furnace, using high precision syringe, lowest in 0.5μl samples, with

intelligent online dilution and concentration function

cheap prodocuts, china suppliers,

Read More

Previous

Escherichia coli portable automatic spectrophotometer Benzene wavelength adjustment...

Previous

Visible Laboratory Spectrophotometer Instruments with LCD Screen...

Macylab Instruments Inc.

Laboratory Spectrophotometer,Double Beam Spectrophotometer,Dual Beam Spectrophotometer

Address: A-711, Haige International Building, Xuanwumen, Xicheng District, Beijing China,
Beijing, Beijing
China, 100000

Tel: 86-010-63014082
Fax: 86-010-63132725

H5响应式定制设计
26种语言,SEO营销型网站


H5/响应式/营销型企业网站; 26种语言扩展;
覆盖: 英文、法语、德语、西班牙语、葡萄牙语、俄语、阿拉伯语、波斯语、日语、韩语
了解更多