?Secondary Injection Protection Relay Testing K3030i , RJ45 Connection
?
1.Easy test
2.operation menu, Simple operation
3.Power:1000VA
1. Unique self-protection system assure the powerful protection when instrument is operating, automatic stop the output when the network is abnormal ;
2. Unique power switch and amplifier technology, so the output precision and power efficiency and factor are increased, which conforms to international tendency of energy save and environmental protection;
3. With alarm function of housing grounding testing and external voltage input, to guaranty personal security;
4. Two in one of meter and source, with function of both internal and external testing, self-calibration, oscillograph, and the duration of each oscillograph reaches 50S (optional function);
5. Offer independent Aux. DC to tested devices, 0 ~ 300V/0.6A (Poleless and adjustable);
6. Function of transducer and energy meter testing (optional function);
7. Testing interface offer unique output monitoring function and Pre-curve-tracing function, helps more on the spot analysis;
?
Technical Data of K3030i?
?
- - - -
Voltage?generators |
Setting? Range | 4-phase?AC?(L-N) | 4?x?0?...?300?V? |
? | 2-phase?AC?(L-L) | 2?x?0?...?600?V |
Power | 4-phase?AC?(L-N) | 4?x?110VA, ?at?0?...?300?V |
? | 2-phase?AC?(L-L) | 2?x?220VA, ?at?0?...?600?V |
Accuracy | <0.07%?reading?+?0.03%?range?guaranteed? at?0?...?300?V <0.02%?reading?+?0.01%?range?typical? at?0-300V |
Resolution | 1mV |
Current?generators |
Setting? Range | 3-phase?AC?(L-N) | 3?x?0?...?30?A |
? | 1-phase?AC?(2L-N) | 1?x?0?...?60?A? |
? | 1-phase?AC?(3L-N) | 1?x?0?...?90?A? |
Power | 3-phase?AC?(L-N) | 3x?450VA?, at?0?...?30A? |
? | 1-phase?AC?(2L-N) | 1x?520VA, ?at?0?...?60A? |
? | 1-phase?AC?(3L-N) | 1?x?1200VA, ?at?0?...?90A?(Max.) |
Accuracy | <0.07%?reading?+?0.06%?range?guaranteed?at?0-30A? <0.02%?reading?+?0.02%?range?typical?at?0-30A |
Resolution | 1mA |
Generators, ?general |
Frequency | Range | 0?...?1000?Hz |
? | Accuracy?/?drift | Error?0.001Hz?at?10?...?65Hz, Error?0.01Hz??at?65Hz...450Hz Error?0.02Hz??at?450Hz...1000Hz |
? | Resolution | 0.001Hz |
Phase | Range | -?360°?...?+360° |
? | Accuracy?/?drift | Error?0.2?° |
? | Resolution | 0.1° |
Timer | Range | Infinite |
? | Accuracy?/?drift | Error<0.1ms |
DC?generators |
Voltage?ranges | 0?...?300V/150W |
Current?ranges | 0?...?20A/300W |
Accuracy | <0.07%?reading?+?0.03%?range?guaranteed?at?0-300V? <0.04%?reading?+?0.02%?range?typical?at?0-300V |
? | <0.14%?reading?+?0.06%?range?guaranteed?at?0-20A <0.05%?reading?+?0.02%?range?typical?at?0-20A |
Resolution | 1mA;?1?mV |
Aux?DC?Supply |
Range | 0...300V/0.6A |
Binary?inputs |
Number | 8?pairs |
Compatible?Voltage | 10V?...?250V??DC |
Binary?outputs |
Number | 4?Pairs |
Capacity | 250V/3A?????AC/DC |
Synchronization |
Synchronization?mode | GPS |
Harmonic |
Harmonic?overlap?times | 2?...?20?times |
Power?supply |
Nominal?input?voltage | 220VAC±20% |
Power | 1000VA |
Nominal?frequency | 47Hz….65Hz |
Environmental?conditions |
Operation?temperature | -5°C?...?55?°C |
Storage?temperature | -20°C?...?75?°C |
Humidity?range | 5%?...?90?%, ?non-condensing |
Weight | 20?KG |
Dimensions | 460(D)×140?(W)×360?(H)?mm |
PC?connection | RJ45, ? |
- - - -
?
K30?Series?Protection?Relay?Test?Set:
?
- - - -
Model | Channels | AC?Outputs |
K3063i?/?K3063Li | 10?output?channels | 6*30A/3*40A/4*300V |
K3030i?/?K3030Li | 7?output?channels | 3*30A/4*300V |
K3066 | 13?output?channels | 6*20A/3*40A/7*130V |
K3063 | 10?output?channels | 6*20A/3*40A/4*130V |
K3040 | 7?output?channels | 3*40A/4*130V |
K3030 | 7?output?channels | 3*30A/4*130V |
- - - -
?
Major?functions:
?
- - - -
Items | IEEE(R)?No. |
Synchronization?relay | ? |
Fault?transplay | ? |
GPS?Synchronization? | ? |
Overcurrent?relays | 50/76 |
Inverse?time?overcurrent?relays | 51 |
Undercurrent?relays | 37 |
Ground?fault?relays | 50 |
Directional?overcurrent?relays | 67 |
Directional?ground?fault?relays | 67N |
Overvoltage?relays | 59 |
Undervoltage?relays | 27 |
Directional?voltage?relays | 91 |
Directional?power?relays | 32 |
Power?factor?relays | 55 |
Differential?protection?(differential?circuits) | 87 |
Distance?protection?equipment?(phase?by?phase) | 21 |
Negative?sequence?overcurrent?relays | 46N |
Motor?overload?protection | 51/86 |
Automatic?reclosing?devices? | 79 |
Tripping?relays | 94 |
Voltage?regulating?relays | ? |
Overimpedance?relays, ?Z> | ? |
Underimpedance?relays, ?Z | ? |
Time-delay?relays | ? |
- - - -
?
?
?