Electronics Production Machinery
Description
Specifications:
?
- - - -
Gas detected | Carbon Dioxide (CO2) |
Sensing element | Non-Depressive Infrared Detector (NDIR) |
CO2 NDIR life | >10 years |
CO2 range | 0~5000ppm
0~20,000ppm or 0~50,000ppm optional |
Accuracy@25℃(77℉) | ±40ppm + 3% of reading (0~5,000ppm)
±75ppm or 10% of reading whichever is greater
(0~20,000ppm or 0~50,000ppm) |
Stability | <2% of FS over life of sensor (15 yr typical) |
Calibration interval | ABC Logic Self Calibration Algorithm |
CO2 setting & Display resolution | 1ppm |
Pressure Dependence | Can be preset the altitude by the end users to eliminate the pressure influence via a inside software |
Temperature& RH sensor (optional) | Combined digital temperature and relative humidity sensor |
Temperature measurement range | 0℃~60℃(32℉~140℉) |
Humidity measurement range | 0~100%RH |
Temperature& RH accuracy | ±0.5℃ / ±3%RH |
Option: 1X dry contact output | Rated currency for contact point: 2A 220VAC/30VDC, resistance load |
Operation condition | 0℃~60℃, 0~95%RH (non-condensing) |
Power supply | 24VAC/VDC ±10% wiring connection
Or with a power adaptor of 24V/230V or 24V/110V |
Consumption | 3.5W/ Max, 2.5W/ Average |
Weight | 380g |
Dimensions | 130mm×90mm×40mm |
Connections Interface | Locate in interface of connection |
Installment standard | 65mm×65mm or 2”×4” wire box |
Wiring standard | Wire section area<1.5mm2 |
Approval Standard | CE-Approval |
Presetting and operation | Buttons and internal DIP switches |
Sampling alternation | Preset the sampling alternation during 60s to 1h. The general maximum
day of the data record is 115 days |
Software Features | Outputs date is in .txt format
USBDataGather software is for stand-alone application. It’s used to set parameters for different applications, to display the graph of capture data, to calculate the average value of a period, as well as the max. and min. value |
- - - -
?
Description:
?
1. Real-time monitoring carbon dioxide (CO2) measurements during 0ppm to 5,000ppm range
2. Optional real-time monitoring temperature from -20℃ to 60℃ and relative humidity from 0 to 100%RH
3. Non-dispersive infrared (NDIR) CO2 sensor with self-calibration, 15 years lifetime
4. The 3-LED indicator lights indicate three CO2 measured ranges
5. LED lights brightness adjustable
6. Easy preset CO2 level for buzzer alert (optional)
7. Provide 1X On/Off dry contact output to control alternative a ventilator and a CO2 generator
8. An internal data logger is used to record CO2 measurements as well as optional temperature and RH% measurements.
9. With super large capability memorizer, it can save data of up to 115 days
10. Provide the software to preset the sampling time, read and record CO2/temperature&RH levels on PC
11. Post the data from the internal memorizer by any USB disk, and copy the data to a PC
?????
?
Applications:
?
The memorial CO2 monitor/controller not only very easily to be used as a CO2 monitor and controller, but also as a recorder of the measurements. Application in schools, kindergartens, office buildings, greenhouses and so on.
?
Buttons/LCD/USB Connection
?
?
?
?
?
Mounting and Dimensions
?
?
?
Models Guide
- - - -
item | model | description |
1 | F2000IAQ-CO2-3100U | CO2 Detector&Monitor with LCD display, 3 LED lights indicates CO2 levels range. Data logger records CO2 measurements with a USB disk to move the data to a PC.
Power supply: 24VAC/VDC |
2 | F2000IAQ-CO2-3101U | CO2 Monitor&Controller with LCD display, 3 LED lights indicates CO2 levels range. 1X relay On/Off control output.
Data logger records CO2 measurements with a USB disk to move the data to a PC. |
3 | Option ?-TH (postfi ?(for above items) | Temperature and RH monitoring and data recordering option for above items. |
- - - -
?
?
Wiring Diagram
?
Read More
Tongdy Control Technology Co., Ltd
CO2 Monitor,CO2 Controller,CO2 Transmitter
Address: Building #8, Courtyard #9, Dijin Rd., Haidian Dist., Beijing 100095, China,
Beijing, Beijing
China, 100095
Tel: 86-10-59738930
Fax: 86-10-59738935