Introduction:
Power Safe series DSP low frequency UPS is the second generation digital on-line LF UPS .It has been designed to provide an optimized price/performance ratio. A number of exceptional features have been carefully selected and built into the Power safe series? without a substantial increase of material contents in order to optimize both performance and cost benefits. The high power protection value of this new generation of this full digital UPS raises?Power safe ?to the best-value-in-the-category UPS.
Application:Data centre, computer house, industry auto control system, Network Servor etc, critical power system.
Main Features:
Fully Digital control technology
Online double conversion with PFC
IGBT refectifer &?Inverter and ?ISO output transformer
Online battery disconnection alarm
Fault problem auto diagnose (Easy Maintenance)
Input power factor above 0.98
Wide input frequency range 40-70HZ
Flexible network monitoring and management
Large LCD display
Cold start and AC start function
Perfect protections
Technical Specifications:
?
- - - -
Model | PS04H | PS06H | PS08H | PS10H | PS310H | PS315H | PS320H | PS330H | PS340H |
Rating capacity | 4KVA | 6KVA | 8KVA | 10KVA | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA |
Phase | 1:1 | 3:1 |
input | P.F | >0.98 | >0.95 |
Rating voltage | 200/208/220/230/240VAC | 380VAC |
Voltage range | Half load110-285V, full load 160-285v | 380VAC±25% |
Rating frequency | 50Hz/60Hz |
frequency range | 40-70Hz |
THDi | <5% | <30% |
Soft start | 0 to 100% , 3 to 5 seconds |
Charge | Float charge | 220VDC |
Current | 5.5A?(extendable) | 12A(extendable) |
Protection | Charge voltage, over current protection, short circuit protection |
Battery | Model | Lead acid maintenance ?free battery |
Rating voltage | 192V? external ?(or inbuilt 7-9ah) | 192/240Vdc(external), |
O/P | P.F. | 0.8(lagging) |
Phase | L+N+G | 3wires+N+G |
Rating voltage | 220/230/240VAC |
Rating frequency | 50Hz/60Hz(Auto-sensing) |
Frequency | <±0.1Hz in battery mode |
Voltage | <±1.5%(static) |
Crest factor | 3:1 |
Wave distortion | Liner load<3%;Nolinear load<5% |
dynamic load voltage instant distortion | Liner load<±5%(from 0-50%-100%) |
Dynamic response recover time | <40ms |
overload capacity | 105%~125%10min;125%~150% 1min; >150%10ms |
transfer time | 0mS(AC-Battery);<4ms(bypass-inverter) |
System | display | LED+LCD |
Efficiency | 100% linear >89% |
Operate temp | 0~40℃ |
Humidity | 0~90% (non-condensing) |
Cooling | Intelligent fan cooling? |
Noise dB | <55 (≤1M) | <60(1M) |
Physics | configuration | Tower, IP21 |
Weight (Kg) | 60 | 68 | 100 | 128 | 150 | 218 | 258 | 320 | 350 |
Dimension?(W×H×D)mm | 210×586×563 | 300×865×580 | 460×950×710 | 470×1050×840 |
? | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? |
- - - -
?
?????????????????????????????????????????????????????????????????????????????????? [WWW.HRDUPS.COM]
Read More
Shenzhen HuaRuiDi Science & Technology Co., Ltd.
Online High Frequency UPS,Online Low Frequency UPS ,Line Interactive UPS
Address: 4th floor No.7 buliding,Changxing High-Tech Industrial Park,
shenzhen, guangdong
China, 518000
Tel: 86-755-81737467
Fax: 86-755-81737252