1000 - 2000kW middle speed HFO fired Generator Set

Applications:

?

homes, small shops & offices, industrial, ships, power plant , hosipital

- - - -
G300-MIDDLE SPEED MARINE DIESEL |
G16V300 | G8300 | G6300 | G6300 |
G8300 | G16V300 |   |   |
- - - -
?

5)X320 MIDDLE SPEED DIESEL ENGINE

- - - -
X16V320 | X8320 | X8320 | X16V320 |
- - - -

?

Competitive Advantage:

1.Successfully build technical cooperation with MAN Diesel & Turbo company;

2.Design and manufacture the lower , middle , highest diesel engine according to the market demand

3.Good after-sales service team

4.Quality recognized by CCS , GL, ABS, BV classification society in the world

Main Specification of 1000-2000kW Diesel Generating Sets (1)

?

- - - -
Generating Set | Model | 1000GF9 | 1000GF10 | 1000GF11 | 1250GF1A | 1250GF2A | 1250GF3A |
Rated power | kW(kVA) | 1000(1250) | 1250(1562.5) |
Rated voltage | kV | 0.4 | 6.3 | 10.5 | 6.3 | 0.4 | 10.5 |
Rated current | A | 1804 | 114.6 | 68.7 | 143.2 | 2255 | 85.9 |
Rated frequency | Hz | 50/60 |
Rated speed | rpm | 500/514 |
Power factor | ? | 0.8(lagging) |
Phase & connection | ? | 3-phase 4-wire | 3-phase 6-wire | 3-phase 4-wire | 3-phase 6-wire |
Overall dimensions L×B×H | mm | 7264×2300×3465 | 7394×2300×3465 |
Net weight | t | 32.5 | 34 |
Diesel Engine | Model | ? | G6300ZD | G6300ZD21 |
Type | ? | Vertical in line, 4-stroke, turbocharged, intercool diesel engine for generating set |
Bore | mm | 300 |
Stroke | mm | 380 |
Total displacement | L | 161 |
Rated power | kW(Ps) | 1125(1530) | 1470(2000) |
1-hour power | kW(Ps) | 1237.5(1683) | 1617(2200) |
Rated speed | rpm | 500/514 | 600 |
Minimum no-load stable speed | rpm | 200 | 200 |
Specific fuel consumption | g/kWh(g/Psh) | 204(150) | 208(153) |
Specific lubricating-oil consumption | g/kWh(g/Psh) | 2.18(1.60) | 2.18(1.60) |
Mean piston speed | m/s | 6.33 | 7.6 |
Compression ratio | ? | 13 | 13 |
Mean effective pressure | MPa(kgf/cm2) | 1.68(17.1) | 1.83(18.6) |
Maximum explosion pressure | MPa(kgf/cm2) | 11.77(120) | 13.73(140) |
Opening pressure of cylinder safety valve | MPa(kgf/cm2) | 14.21(145) | 15.19(155) |
Idle compression pressure | MPa(kgf/cm2) | 3.14-3.53(32-36) | 3.14-3.53(32-36) |
Turbocharger pressure | MPa(kgf/cm2) | 0.23-0.255(2.35-2.6) | 0.25-0.28(2.5-2.85) |
Exhaust temperature of cylinder | ℃ | ≤450 |
Exhaust temperature before turbine | ℃ | ≤600 |
Rotation direction | ? | Counterclockwise (viewing from flywheel end to free end) |
Firing order | ? | 1-4-2-6-3-5 |
Starting air pressure | MPa(kgf/cm2) | 1.18-2.94(12-30) |
Overall dimensions | L×B×H mm | 4731×1863×2900 | 7394×2300×3465 |
Height of hoisting piston | mm | 2425? (above crankshaft) |
Net weight | t | 17.5 |
Generator | Model | ? | TFW500, TFW900 | TFW900 |
Rated power | kW | 1000 | 1250 |
Rated voltage | kV | 0.4 | 6.3 | 10.5 | 6.3 | 0.4 | 10.5 |
Rated current | A | 1804 | 114.6 | 68.7 | 143.2 | 2255 | 85.9 |
Rated frequency | Hz | 50/60 |
Rated speed | rpm | 500/514 |
Pole number | ? | 12/14 |
- - - -

?

?

Main Specification of 1000-2000kW Diesel Generating Sets (2)

?

- - - -
Generating Set | Model | ? | ? | ? | 1250GF1 | 1250GF2 | 1250GF3 |
Rated power | kW(kVA) | ? | 1250(1562.5) |
Rated voltage | kV | ? | ? | ? | 6.3 | 0.4 | 10.5 |
Rated current | A | ? | ? | ? | 143.2 | 2255 | 85.9 |
Rated frequency | Hz | 50/60 |
Rated speed | rpm | 500/514 |
Power factor | ? | 0.8(lagging) |
Phase & connection | ? | ? | 3-phase 6-wire | 3-phase 4-wire | 3-phase 6-wire |
Overall dimensions L×B×H | mm | ? | 8904×2200×3286 | ?9004×2360×3286 |
Net weight | t | ? | 38 | 39.7 |
Diesel Engine | Model | ? | ? | G8300ZD |
Type | ? | Vertical in line, 4-stroke, turbocharged, intercool diesel engine for generating set |
Bore | mm | 300 |
Stroke | mm | 380 |
Total displacement | L | ? | 215 |
Rated power | kW(Ps) | ? | 1500(2040) |
1-hour power | kW(Ps) | ? | 1650(2244) |
Rated speed | rpm | 500/514 |
Minimum no-load stable speed | rpm | 200 |
Specific fuel consumption | g/kWh(g/Psh) | 204(150) |
Specific lubricating-oil consumption | g/kWh(g/Psh) | 2.18(1.60) |
Mean piston speed | m/s | 6.33 |
Compression ratio | ? | 13 |
Mean effective pressure | MPa(kgf/cm2) | 1.68(17.1) |
Maximum explosion pressure | MPa(kgf/cm2) | 11.77(120) |
Opening pressure of cylinder safety valve | MPa(kgf/cm2) | 14.21(145) |
Idle compression pressure | MPa(kgf/cm2) | 3.14-3.53(32-36) |
Turbocharger pressure | MPa(kgf/cm2) | 0.23-0.255(2.35-2.6) |
Exhaust temperature of cylinder | ℃ | ≤450 |
Exhaust temperature before turbine | ℃ | ≤600 |
Rotation direction | ? | Counterclockwise (viewing from flywheel end to free end) |
Firing order | ? | ? | 1-6-2-4-8-3-7-5 |
Starting air pressure | MPa(kgf/cm2) | 1.18-2.94(12-30) |
Overall dimensions | L×B×H mm | ? | 5768×1670×2917 |
Height of hoisting piston | mm | 2425? (above crankshaft) |
Net weight | t | ? | 21 |
Generator | Model | ? | ? | TFW900 |
Rated power | kW | ? | 1250 |
Rated voltage | kV | ? | ? | ? | 6.3 | 0.4 | 10.5 |
Rated current | A | ? | ? | ? | 143.2 | 2255 | 85.9 |
Rated frequency | Hz | 50/60 |
Rated speed | rpm | 500/514 |
Pole number | ? | 12/14 |
? | ? | ? | ? | ? | ? | ? | ? | ? | ? |
- - - -

?

?

Main Specification of 1000-1600kW Diesel Generating Sets (3)

?

- - - -
Generating Set | Model | 1600GF1 | 1600GF2 | 1600GF3 | 2000GF1 | 2000GF2 | 2000GF3 |
Rated power | kW(kVA) | 1600(2000) | 2000(2500) |
Rated voltage | kV | 6.3 | 0.4 | 10.5 | 6.3 | 0.4 | 10.5 |
Rated current | A | 183 | 2886.7 | 110 | 229 | 3608.6 | 137.5 |
Rated frequency | Hz | 50/60 |
Rated speed | rpm | 500/514 | 600 |
Power factor | ? | 0.8(lagging) |
Phase & connection | ? | 3-phase 6-wire | 3-phase 4-wire | 3-phase 6-wire | 3-phase 4-wire | 3-phase 6-wire |
Overall dimensions L×B×H | mm | 9124×2360×3286 | 9263×2565×3286 |
Net weight | t | 40 | 45 |
Diesel Engine | Model | ? | G8300ZD13 | G8300ZD21 |
Type | ? | Vertical in line, 4-stroke, turbocharged, intercool diesel engine for generating set |
Bore | mm | 300 |
Stroke | mm | 380 |
Total displacement | L | 215 |
Rated power | kW(Ps) | 1765(2400) | 2206(3000) |
1-hour power | kW(Ps) | 1942(2640) | 2426(3300) |
Rated speed | rpm | 500/514 | 600 |
Minimum no-load stable speed | rpm | 200 | 200 |
Specific fuel consumption | g/kWh(g/Psh) | 204(150) | 208(153) |
Specific lubricating-oil consumption | g/kWh(g/Psh) | 2.18(1.60) | 2.18(1.60) |
Mean piston speed | m/s | 6.33 | 7.6 |
Compression ratio | ? | 13 | 13 |
Mean effective pressure | MPa(kgf/cm2) | 2(20.4) | 2.05(20.9) |
Maximum explosion pressure | MPa(kgf/cm2) | 12.75(130) | 13.73(140) |
Opening pressure of cylinder safety valve | MPa(kgf/cm2) | 15.19(155) | 15.19(155) |
Idle compression pressure | MPa(kgf/cm2) | 3.14-3.53(32-36) |
Turbocharger pressure | MPa(kgf/cm2) | 0.23-0.255(2.35-2.6) |
Exhaust temperature of cylinder | ℃ | ≤450 |
Exhaust temperature before turbine | ℃ | ≤600 |
Rotation direction | ? | Counterclockwise (viewing from flywheel end to free end) |
Firing order | ? | 1-6-2-4-8-3-7-5 |
Starting air pressure | MPa(kgf/cm2) | 1.18-2.94(12-30) |
Overall dimensions | L×B×H mm | 5768×1670×2917 | 5818×1670×2917 |
Height of hoisting piston | mm | 2425? (above crankshaft) |
Net weight | t | 21 | 24 |
Generator | Model | ? | TFW900 |
Rated power | kW | 1600 | 2000 |
Rated voltage | kV | 6.3 | 0.4 | 10.5 | 6.3 | 0.4 | 10.5 |
Rated current | A | 183 | 2886.7 | 110 | 229 | 3608.6 | 137.5 |
Rated frequency | Hz | 50/60 |
Rated speed | rpm | 500/514 | 600 |
Pole number | ? | 12/14 | 10/12 |
- - - -

cheap prodocuts, china suppliers,

Read More

Previous

Silent Diesel Engine Generator Set 250kVA For Hosipital CCS Approved...

Previous

Electrical 200-400KW 50 / 60 Hz 3 Phase Marine Diesel engine(M/E)...

Wuxi Kangwei Environment Energy Equipment Company

Genset Power Plant,HFO Fired Power Plant,Waste to Energy Power Plants

Address: NO.8, YINGHUI ROAD,
Wuxi, Jiangsu
China, 214000

Tel: 86-510-85990011
Fax: 86-510-85115375

H5响应式定制设计
26种语言,SEO营销型网站


H5/响应式/营销型企业网站; 26种语言扩展;
覆盖: 英文、法语、德语、西班牙语、葡萄牙语、俄语、阿拉伯语、波斯语、日语、韩语
了解更多