Power Transmission Equipment
6 * 2MW HFO Fired Power Plant , Electric Power Station Four Stroke Generator Set
According to the design and technical demand
Description
?
?
- - - -
Technical specificaiton for HFO ?Power plant equipments? |
Ⅰ. Gen-set technical specification |
No. | Item | Unit | Specification |
1 | Model | | 1250/2000/2500/3500GF |
2 | Rated power? | kW? | 1250/2000/250003500 |
3 | Rated rev. | rpm | 600 |
4 | Rated voltage | V | 11000 |
5 | Rated current? | A | 229.6 |
6 | Frequency? | Hz | 50Hz |
7 | Power factor | | 0.8 (lagging) |
8 | Phase | | 3-phase? |
9 | Voltage fluctuation rate | % | ±1 |
10 | Frequency (rev.)??fluctuation rate | % | ±0.5 |
11 | Stable voltage regulating rate | % | ±2.5 |
12 | Stable frequency (rev.) regulating rate | % | 5 |
13 | Transient?voltage?regulating rate | % | ±20~-15 |
14 | Stabilizing time | s | 5 |
15 | Voltage regulating method | | Auto? |
16 | Speed Governor | | Electronic?hydraulic |
17 | Frequency regulating method | | Auto/Manual? |
18 | Lubricating method | | Pressure lubricating |
19 | Cooling method? | | Close circuit of fresh cooling water |
20 | Coupling? | | Flexiable |
21 | Painting color | | Blue |
22 | Overall dimension | mm | 9890x2560x4015 |
23 | Net weight | kg | 75000 |
Ⅱ. Diesel engine specification |
No. | Item | Unit | Specification |
1 | Engine Model | | DN8340ZD2 |
2 | Type | | In-line, 8-Cyls, four-stroke, direct injection, charged, inter cooled |
3 | Bore | mm | 340 |
4 | Stroke? | mm | 450 |
5 | Total displacemen | L | 408.35 |
6 | Mean piston seed? | m/s | 9 |
7 | Rated power | KW | 4200 |
8 | Rated rev. | rpm | 600 |
9 | Overload??(1 hr per 12 hrs)??????????????????????? | kW/rpm | 4620/600 |
10 | Mean effective pressure | MPa | 2.56 |
11 | Compression ratio | | 13.5 |
12 | Rotation direction | | Clockwise, viewed from flywheel end. |
13 | Firing order | | 1-4-7-6-8-5-2-3 |
14 | Specific fuel oil consumption | g/kW.h | 198+3% |
15 | Specific Lube oil consumption | g/kW.h | < 1.2g/kW.h |
16 | Smoke | RB | ≤0.3 |
17 | Noise | dB(A) | 105 |
18 | Starting method | | Air Rotary valve |
19 | Cooling system | | Fresh water cooling |
20 | Lubricating system | | Pressure lubricating |
21 | Fuel oil specification | | Diesel oil and?720Cst/50℃ HFO |
22 | Lube oil specification | | CD40 with TBN according HFO |
23 | Piston lifting height | mm | 2365 |
24 | Overall dimension | mm | 7213×1850×3625mm |
25 | Net weight | kg | 47000 |
Ⅲ. Alternator specification |
No. | Item | Unit | Specification |
1 | Alternator Model | | TFW3800 |
2 | Type | | Brushless??generator |
3 | Rated power | kW? | 3500 |
4 | Rated voltage | V | 11000 |
5 | Rated current | A | 229.6 |
6 | Frequency | Hz | 50 |
7 | Power factor | | 0.8 (lagging) |
8 | Working condition | | Continuous |
9 | Phase and connection | | 3-phase |
10 | Voltage regulation method | | Brushless, self excited |
11 | Insulation Class | | F |
12 | Protection Class | | IP23 |
Ⅳ Cooling tower?specification |
No. | Item | Unit | Specification |
1 | Cooling tower model | | GBL-150 |
2 | Inlet temperature | ℃ | 60 |
3 | Outlet? | ℃ | 35 |
4 | Base Plane?Size | mm | Ф4460×5095 |
5 | Blade amount | | 4 |
6 | Fan diameter | mm | Ф3400 |
7 | Motor fan power | kW | 11 |
8 | Inlet pipe demension | mm | DN200 |
9 | Outlet pipe demension | mm | DN250 |
- - - -
?
?
?The power fuel can be diesel oil, bio-diesel, heavy fuel oil (HFO) or bi-fuel
?
- - - -
G300 Statinary Generating Sets Main Specification |
Model | 1000GF1 | 1250GF3 | 1350GF4 | 1400GF4 |
Rated power, KW | 1000 | 1250 | 1350 | 1400 |
Overload , KW | 1100 | 1375 | 1485 | 1540 |
Rated voltage, V | 400/415/440/3300/6300/10500/13800 |
Rated current , A | | | | | | | | |
Frequency , Hz | 50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
Power factor | 0.8 Lagging |
Phase | 3 |
Diesel engine | G6300ZD6 | G6300ZD8 | G8300ZD6 | G6300ZD10 | G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 |
Rated power, KW | 1103 | 1470 | 1471 | 1471 | 1765 | 2000 | 1765 | 2000 |
Rated rev, rpm | 500 | 600 | 500 | 600 | 500 | 600 | 500 | 600 |
Alternator | 3 phase alternator |
voltage fluctuation rate% | <0.5 | <0.5 |
Frequency fluctuation rate, % | <0.5 | <0.5 |
Stable voltage regulating rate, % | ±1.0 | ±1.0 |
Transient voltage regulating rate, % | +20, -15 | +20, -15 |
Stable Frequency fluctuation rate, % | <3 | <0.5 |
Transient frequency regulating rate, % | +12, -10 |
Stablizing time, voltage , S | <4 |
Stablizing time, frequency , S | <3 |
voltage regulating method | automatic and munual |
Frequency regulating method | manual |
starting method | compressed air |
Lubricating method | pressue lubricating? |
Cooking method | water cooling |
coupling | flexible |
Overdimension, mm | 3880*2150*3180 | 8470*2360*3060 |
Weight, Kg | 30000 | 35000 | 38000 |
- - - -
- - - -
G300 Statinary Generating Sets Main Specification |
1500GF6 | 1600GF5 | 1800GF7 | 2000GF8 |
1500 | 1600 | 1800 | 2000 |
1650 | 1760 | 1980 | 2200 |
400/415/440/3300/6300/10500/13800 |
| | | | | | | |
50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
0.8 Lagging |
3 |
G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 | G8300ZD8 | G8300ZD8 | G8300ZD12 | G8300ZD8 |
1765 | 2000 | 1765 | 2000 | 2000 | 2000 | 2206 | 2000 |
500 | 600 | 500 | 600 | 600 | 600 | 600 | 600 |
3 phase alternator |
<0.5 |
<0.5 |
±1.0 |
20, -15 |
<0.5 |
+20, -15 |
<5 |
<4 |
automatic and munual |
manual |
compressed air |
pressue lubricating? |
water cooling |
flexible |
8470*2360*3060 |
38000 | 42560 |
- - - -
?
?
Remark
?
1.the generator voltage and frequency can be selected
2.rating for the generator set is based on the following standard conditions
air temperature :25℃
total barometric pressure 100kpa
charge air coolant temperature 25℃
relative humidity 30%
If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000
3.The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position
?
- - - -
GN8320 Stationary Generating Sets Main Specification |
Model | 2400GF | 2500GF |
Rated power, KW | 2400 | 2500 |
Overload , KW | 2640 | 2750 |
Rated voltage, V | 400 | 415 | 3300 | 6300 | 10500 | 400 | 415 | 3300 | 6300 | 10500 |
Rated current , A | 4330 | 4174 | 525 | 275 | 165 | 4511 | 4348 | 547 | 172 | 286 |
Frequency , Hz | 50 | 50 |
Power factor | 0.8 Lagging | 0.8 Lagging |
Phase | 3 | 3 |
Diesel engine | GN832000ZD | GN8320ZD |
Rated power, KW | 2648 | 2795 |
Rated rev, rpm | 750 | 750 |
Alternator | 3 phase alternator |
voltage fluctuation rate% | ±1.0 |
Frequency fluctuation rate, % | +12, -10 |
Stable voltage regulating rate, % | 3 |
Transient voltage regulating rate, % | +12, -10 |
Stable Frequency fluctuation rate, % | 4 ? |
Transient frequency regulating rate, % | 5 |
Stabilizing time, voltage , S | +1 |
Stabilizing time, frequency , S | +12, -10 |
voltage regulating method | automatic and manual |
Frequency regulating method | manual |
starting method | compressed air |
Lubricating method | pressure lubricating |
Cooking method | water cooling |
coupling | flexible |
Overdimension, mm | 8950*2570*6050 |
Weight, Kg | 45000 |
- - - -
?
?
Remark
?
1.the generator voltage and frequency can be selected
2.rating for the generator set is based on the following standard conditions
air temperature :25℃
total barometric pressure
charge air coolant temperature
?
?
relative humidity
?
If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000
3.The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position
?
Read More
Wuxi Kangwei Environment Energy Equipment Company
Genset Power Plant,HFO Fired Power Plant,Waste to Energy Power Plants
Address: NO.8, YINGHUI ROAD,
Wuxi, Jiangsu
China, 214000
Tel: 86-510-85990011
Fax: 86-510-85115375