Optoelectronic Displays
High Efficiency 90 - 264 VAC Power Supply Rectifier For Telecom Equipment JPS250PS48C
JPS250PS48C
Description
High Efficiency 90 - 264 VAC Telecom Power Supplies For Telecom Equipment JPS250PS48C
JPS250PS48C
?
200?W?with?Convection?Cooling
High?Efficiency?-?up?to?88%
Meets?1U,?Low?Profile?Requirements
AC?OK?&?DC?OK?Signals
Zero?Voltage?Switching?Technology
Remote?On/Off?&?Remote?Sense
Current?Share
?
- - - -
Model?Number | JPS250PS48C |
Manufacturer | XP?POWER |
- - - -
?
Input
Input?Voltage????????????90-264?VAC?(170-370?VDC)
Input?Frequency??????????47-63?Hz
Input?Current????????????2.75?A/1.40?A?max?at?115?VAC/230?VAC
Inrush?Current???????????30?A?at?115?VAC,?60?A?at?230?VAC
Power?Factor????????????0.99?typical
Earth?Leakage?Current?????2.0?mA?max?264?VAC/60?Hz
Input?Protection??????????Internal?5?A,?250?V?fuse
?
Output
Output?Voltage?Trim?????±10%?on?output?1?only
Initial?Set?Accuracy?????At?60%?rated?load?±1%?on?V1?&?V2,
±5%?on?V3?&?V4
Minimum?Load?????????Single?output?models:?No?minimum?load
required.?Multi-output?models,?see?note?4
Start?Up?Delay??????????2?s?typical
Start?Up?Rise?Time??????80?ms?typical
Hold?Up?Time??????????20?ms?min?at?low?line?&?rated?load
Line?Regulation?????????±0.5%?at?rated?load?across?input
voltage?range
Load?Regulation?????????±1%?for?single?output?models?&?V1?&?V2
of?multi-output?models,?±5%?for?V3?&?V4
Transient?Response??????4%?max?deviation,?recovery?to?within
1%?in?500?μs?for?a?25%?load?change
Ripple?&?Noise??????????±1%?max?pk-pk,?20?MHz?BW
Overvoltage?Protection???115-140%?on?single?outputs?&?V1?of?quad
output?models,?recycle?input?to?reset
Overtemperature?????????Shuts?down?at?+110?°C,?auto?recovery
Protection??????????????measured?internally
Overload?Protection??????110-130%?of?max?rated?load?on?all?O/Ps,
trip?&?restart?(Hiccup?mode),?auto?recovery
Short?Circuit?Protection????Trip?and?restart?(Hiccup?mode)
Temperature?????????????±0.05%/°C
Coefficient
Remote?Sense???????????Compensates?for?up?to?0.5?V?drop
Remote?On/Off??????????On?=?Logic?Low?or?Open,?Off?=?Logic?High
Current?Share???????????Single?wire?current?sharing?on?single
output?models?&?V1?&?V2?of?multi-output
models?(4?supplies?can?be?paralleled)
Fan?Output?????????????5?V?model:?5?V?at?390?mA,
24?V?model:?24?V?at?80?mA,
all?other?models:?12?V?at?112?mA
General
Efficiency???????????????Up?to?88%
Isolation????????????????3000?VAC?Input?to?Output
1500?VAC?Input?to?Ground
500?VAC?Output?to?Ground
Switching?Frequency??????120?kHz?typical?for?PFC?and?PWM
Power?Density????????????4.96?W/In3
Signals?????????????????AC?OK,?DC?OK,?Remote?On/Off
(see?control?and?supervisory?signals)
MTBF??????????????????255?kHrs?per?MIL-HDBK-217F?at?+25?°C
?
?
Environmental
Operating?Temperature?????0?°C?to?+70?°C,?(see?derating?curve)
Full?power?to?+50?°C
Cooling????????????????250?W?with?18?CFM?airflow
200?W?convection?cooling
Operating?Humidity???????5-95%?RH,?non-condensing
Storage?Temperature??????-20?°C?to?+85?°C
Operating?Altitude????????3000?m
Vibration???????????????2?g,?10?Hz?to?55?Hz,
3?mins/cycle?for?30?mins?each?axis
?
EMC?&?Safety
Emissions?????????????EN55022,?level?B?conducted
FCC?20780,?level?B?conducted
Harmonic?Currents??????EN61000-3-2
Voltage?Flicker?????????EN61000-3-3
ESD?Immunity?????????EN61000-4-2,?level?3?Perf?Criteria?A
Radiated?Immunity??????EN61000-4-3,?10?V/m?Perf?Criteria?A
EFT/Burst?????????????EN61000-4-4,?level?3?Perf?Criteria?A
Surge?????????????????EN61000-4-5,?level?3?Perf?Criteria?A
Safety?Approvals????????EN60950-1:2001,?UL60950-1,
CSA?C22.2?No.?60950-1-03,
CE?Mark?LVD
?
Read More
Oriental Components Limited
Siemens EWSD,Ericsson MD110,Siemens BSC
Address: 4E Aozhihao Complex Building, Xinzhou 4th Street, Futian Disctrict, Shenzhen China,
Shenzhen, Guangdong
China, 518000
Tel: 86-0755-82717080
Fax: 86-0755-82717052