Electronics Projects
2 Core Silicone Fire Resistant cable , Low Smoke Fire Alarm Cable with Copper Conductor
КПС нг(А)-FRLS 2 Cores
Description
?
2 Core Silicone Fire Resistant cable , Low Smoke Fire Alarm Cable with Copper Conductor
?
?
Quick Detail:
?
КПС нг(А)-FRLS cable
2 Cores Copper Conductor
Silicone Insulation
Fire Resistance Low Smoke
200m Reel, Carton, Pallet
180 minutes under fire of 750 degrees without short-circuit.
More details please contact us!
?
?
Description:
?
KT1400 КПС нг(А)-FRLS Fire Resistant cable 2 Cores Silicone??
is a specific type of fire alarm cable Produced by KINGTONE. These cables are used for
installation in fire systems for connecting fire alarms etc. The cable can be installed
in dry and moist areas as well for fixed open air installation. This cable type with
electrostatic screening (St) protects the transmission circuits against extern-electrical
interferences. And all these cables comply to:
IEC60331-23-2003??????????????
IEC60332-3-22-2005
IEC61034-2-2005????????????????
EC60754-1-99
IEC60754-2-99???????????????????
IEC60331-21:1999
BS EN 61034-2:2005?????????????
BS 7629-1:2008
BS EN 50267-2-1:1999
KINGTONE using best raw material and best worker to produce RКПС нг(А)-FRLS
Unshielded 2 Cores to meet high performance in practical application. КПС нг(А)-FRLS
Unshielded 2 Cores is packed in 200m Reel, 2~10 Reels /Carton, then will be layed on
pallet to protect the spool and easier carry.Because of good managing methods,
KINGTONE’S price of КПС нг(А)-FRLS Unshielded 2 Cores is not high although
our quality is really high.
?
?
Applications:
?
These cables are used for installation in fire systems for connecting fire alarms etc.
The cable can be installed in dry and moist areas as well for fixed open air installation.
This cable type with electrostatic screening (St) protects the transmission circuits
against extern-electrical interferences.
?
- - - -
KT1400?КПС?нг(А)-FRLS?Fire?resistant?cable?2?Cores?
Copper?Silicone?Insulation |
APPLICATION: |
These?cables?are?used?for?installation?in?fire?systems?for?connecting?fire?alarms?etc.?
The?cable?can?be?installed?in?dry?and?moist?areasas?well?for?fixed?open?air?installation.?
This?cable?type?with?electrostatic?screening?(St)?protects?the?transmission?circuits?
against?externelectrical?interferences. |
Standards: |
All?these?cables?comply?to:? |
IEC60331-23-2003??????????????
IEC61034-2-2005????????????????
IEC60754-2-99??????????????????? | IEC60332-3-22-2005
IEC60754-1-99
IEC60331-21:1999 | ? | BS?7629-1:2008
BS?EN?61034-2:2005???????????
BS?EN?50267-2-1:1999 |
Fire?Testing: |
180?minutes?under?fire?of?750?degrees?without?short-circuit. |
? |
ELECTRICAL?DATA?(AT20OC): |
Minimum??
Bend?Radius | ? | Min.Insulation?
resistance | Max.Working?
Temperature | Test?voltage??????????
(rms?value) | Max.?Operating?
voltage?peak?value |
? | ? | MΩ/km | ?℃ | V | V |
8×Diameter | ? | 200 | -15℃~+90℃ | 1000 | 300 |
? |
TYPES?AND?MECHANICAL?DATA: |
Types??????????????????
sqmm?(mm2) | Conductor?????
BC?(mm) | Insulation | Level?of?
twisting | Jacket?Matterial | OD?of?
Jacket?(mm) |
2×0.22 | 1×2×0.50? | Silicone | ? | FRLS | 4.10? |
2×0.5 | 1×2×0.76? | Silicone | ? | FRLS | 5.00? |
2×0.75 | 1×2×0.94? | Silicone | ? | FRLS | 5.90? |
2×1.0 | 1×2×1.07? | Silicone | ? | FRLS | 6.30? |
2×1.5 | 1×2×1.35? | Silicone | ? | FRLS | 6.90? |
2×2.5 | 1×2×1.70? | Silicone | ? | FRLS | 8.00? |
??*Notes | Class?1:?Solid | BC: | Bare?Copper | ? |
Order?Informations: |
??Marking | KINGTONE?KT1400?КПС?нг(А)-FRLS?Cable?2×***MM2? CABLE?MMDDYYYY |
??Package | 100m/Roll,200m/Roll,?300m/Spool,Pallet |
??More?info. | Please?contact?with?us. |
- - - -
?
?
Competitive Advantage:
?
1, ?From raw materials to final products, we perform intense quality checks to maintain our product quality:
? ? ?A, Incoming material inspected by QC.
? ? ?B, Manufacturing Process Control
? ? ?C: Workers trained daily/weekly/monthly
? ? ?D: Work instructions manual at each work station
? ? ?E: 5S system implemented
? ? ?F: Machine maintenance procedure
? ? ?G: Quality Control and Final Inspection?
? ? ? ? ?The QC staff will check the material, process product
? ? ? ? ?and final product according to the specification or test procedure.
2, Our R&D efforts center on reinforcing and developing element technologies
? ? needed to support the future growth and success for customers and KINGTONE.
3, We know customers have urgent needs.
? ? We are skilled at effective communication to interact with customers.
? ? In order to provide prompt service, we can answer for you 7*24 hours.
4, We can Quickly and professionally answer for the inquire
5, More than 1000 kinds of cable, connectors and assembles can be produce and organized from us