Electronic Signs

Share us

Steel Tape Armoured Wire of Copper PVC ( Polyvinyl Chloride ) XLPE Insulated Cable

8.7/10 KV 3*150 YJV22

Description

Steel Tape Armoured of Wire of Copper PVC ( Polyvinyl Chloride ) XLPE Insulated Cable ? ? Specifications
?
Description: Price of Wire of Copper


Specification: 8.7/10 KV 3*150 YJV22

?

?



Application:

?


It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower.

?

It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and

?

communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC

insulated power cable.

?

?

The type, Name, Suitable areas

?

- - - -
Type | ? Name | ? Suitable areas |
Copper-conductor | ? AL-conductor |
YJV | YJLV | ? XLPE-insulated cable sheathed with PVC | Indoor, tunnel, cable channel |
YJY | YJLY | ? XLPE-insulated cable sheathed with polythene |
YJV22 | YJLV22 | ? XLPE-insulated cable sheathed with PVC and armored with steel tape | ? Direct burial in the ground and the capacity of bearing certain mechanical force, not proper in the pipeline |
YJV23 | YJLV23 | ? XLPE-insulated cable sheathed with polythene and armored with steel tape |
YJV32 | YJLV32 | ? XLPE-insulated cable sheathed with PVC and armored with thin steel wire | ? The bed of river and shallow sea, as the link line between the two platforms of oil and gas station in the water, the capacity of bearing tensile force. |
YJV33 | YJLV33 | ? XLPE-insulated cable sheathed with polythene and armored with thin steel wire |
YJV42 | YJLV42 | ? XLPE-insulated cable sheathed with PVC and armored with thick steel wire |
- - - -

?


Using Features:


1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.


2. No. of core: Single-core, Three-core.


3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250.


4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997.


5. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.


6.The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.


7. Working Frequency Voltage Test:.


For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.


8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.

?

?

This series includes:

?

Copper (aluminum) core, XLPE insulated and sheathed power cables.


Copper (aluminum) core, XLPE insulated, PE sheathed power cables.


Copper (aluminum) core, XLPE insulated, steel tape armoring PVC sheathed power cables.


Copper (aluminum) core, XLPE insulated, steel tape armoring, PE sheathed power cables.


Copper (aluminum) core, XLPE insulated, steel wire armoring, PVC sheathed power Cables.


Copper (aluminum) core, XLPE insulated, steel wire armoring, PE sheathed power cables


Rated voltage: 0.6/1kV, 3.6/6kV.


Number of cores: 1 to 6.


Relative manufacturing standards: IEC60505, BS, DIN.

?

Packing: Wooden drum, steel wooden drum.

?

Power Cable


-Conductor:
Solid or stranded copper


-Insulation:
Cross-linked polyethylene( XLPE or PVC)


-Circuit Identication:
The insulation shall be red, black


-Filler:
Polypropylene lament with lapped binding tape


-Inner Sheath:
Polyvinyl chloride (Black)


-Armor:
Galvanized steel wire


-Core-covering:
Binding tape


-Outer Sheath:
Polyvinyl chloride (Black)


-Application:
For use in ducts, trays and direct burial in ground. The cable is subject to immerse in water all the time.


-Standards / Testing Specications:
IEC 60502-1.

?


Installation


This cable can be installed in duct, tray or direct burial.

It is recommended that the installation instructions indicated by the Local Electric Code,

or any equivalent, be followed,so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.

?


1.The products are mainly complying with IEC 60502 standard, also can be produced according to OEM requirements and other standards, such as BS standard, DIN standard, ASTM standard, etc.


Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or aluminiun conductor).

?

Conductor long-time operating temperature is 90 degrees. In short circuit, conductor highest temperature should be not more than 250 degrees.

?


2. Brief Construction:


Single core or multi-core

Copper or aluminium conductor

XLPE insulation

Copper tape or copper wire screen

Galvanized steel wire armored

PVC or PE sheath

?

?

The Framework of our Management:

?



?

The Main Process of Production :



?

?

The finished goods with packaged :



?

cheap prodocuts, china suppliers,

Read More

Previous

High Performance XLPE Insulated Cable Aluminum Wire with Rubble Jacket 1*300 mm2...

Previous

Professioanl XLPE Insulated Cable Coaxial With PVC Jacket 230 / 400kv...

Shandong Luda Packing Co.,Ltd

stretch film .paper corner ,plywood box ,adhesive tape

Address: Room No.1302,Huangtai E-commerce industrial park,Lishan North Road,TianQiao District,Jinan City,Shandong Province,China,
Jinan, Shandong
China, 250000

Tel: 15376875220
Fax: 53181258989

H5响应式定制设计
26种语言,SEO营销型网站


H5/响应式/营销型企业网站; 26种语言扩展;
覆盖: 英文、法语、德语、西班牙语、葡萄牙语、俄语、阿拉伯语、波斯语、日语、韩语
了解更多